slau358q.pdf - 第27页

www.ti.com Programming MSP Flash Devices Using the MSP Gang Programmer 27 SLAU358Q – September 2011 – Revised October 2019 Submit Documentation Feedback Copyright © 2011–2019, Texas Instruments Incorporated Operation IF …

100%1 / 142
Programming MSP Flash Devices Using the MSP Gang Programmer
www.ti.com
26
SLAU358QSeptember 2011Revised October 2019
Submit Documentation Feedback
Copyright © 2011–2019, Texas Instruments Incorporated
Operation
2.1.3.2 Command Syntax
White spaces before instructions, labels, and comments are ignored.
; Start of a comment. All characters in the same line after the start of a comment are ignored.
NOTE: A comment cannot be placed after a filename.
For example, when specifying a config file to be loaded, a path to a file must be given. This
filename cannot be followed by a comment.
> Start of a label. Place the label name after the character with no spaces in between.
NOTE: A line with a label cannot also contain a command or another label.
For example, this would be illegal:
>START VCCOFF
2.1.3.3 Instructions
MESSAGE Message declaration. Contents must be placed between quotes below a message
declaration. Maximum of 50 content lines. Example:
MESSAGE "Hello." "This is my script."
GUIMSGBOX setting Enable or disable pop-up message boxes in the GUI (warning and errors). Setting
can be either ENABLE or DISABLE.
IFGUIMSGBOXPRESS option Apply the option when a message box created by GUI is generated.
Option can be OK or CANCEL.
MESSAGEBOX type Create a pop-up message box with buttons. Contents must be placed between
quotes below message declaration. Maximum of 50 content lines. Message box types are:
OK One button: OK.
OKCANCEL Two buttons: OK and CANCEL
YESNO Two buttons: YES and NO
YESNOCANCEL Three buttons: YES, NO, and CANCEL
Example:
MESSAGE YESNOCANCEL
"You have three choices:"
"Press yes, no, or cancel."
GOTO label Jump to instruction immediately following the label.
SLEEP number Pause a number of milliseconds, between 1 and 100000.
F_LOADPASSWORDFILE filename Load JTAG password file. Provide a full path and filename.
F_FROMIMAGEMODE Switch to Image mode.
CALL label Call procedure starting at the instruction immediately following the label. Stack saves return
address.
RETURN Return from CALL.
www.ti.com
Programming MSP Flash Devices Using the MSP Gang Programmer
27
SLAU358QSeptember 2011Revised October 2019
Submit Documentation Feedback
Copyright © 2011–2019, Texas Instruments Incorporated
Operation
IF condition operation Test condition and if true then perform operation. The condition can be one of
the following:
BUTTONOK OK button is pressed in the message box.
BUTTONYES YES button is pressed in the message box.
BUTTONNO NO button is pressed in the message box.
BUTTONCANCEL CANCEL button is pressed in the message box.
DONE Previous process (for example, GO or Read File) finished successfully.
FAILED Previous process (for example, GO or Read File) failed.
The operation can be one of the following:
GOTO label
CALL label SLEEP number Pause a number of milliseconds, between 1 and 100000.
F_LOADCFGFILE filename Load configuration file. Provide a full path and filename.
F_LOADCODEFILE filename Load code file. Provide a full path and filename.
F_APPENDCODEFILE filename Append code file. Provide a full path and file name.
F_VCCOFF Turn V
CC
OFF from programming adapter to target device.
F_VCCON Turn V
CC
ON from programming adapter to target device.
NOTE: V
CC
from FPA must be enabled first using configuration file.
F_VCCINMV Set V
CC
in mV, between 1800 to 3600 in steps of 100 mV.
F_RESET Perform RESET function from main dialog screen.
F_GO Perform GO function from main dialog screen.
F_ERASEFLASH Perform ERASE FLASH function from main dialog screen.
F_BLANKCHECK Perform BLANK CHECK function from main dialog screen.
F_WRITEFLASH Perform WRITE FLASH function from main dialog screen.
F_VERIFYFLASH Perform VERIFY FLASH function from main dialog screen.
F_BLOWFUSE Perform BLOW FUSE function from main dialog screen.
NOTE: Blows fuse regardless of enable option.
If the BLOW FUSE command is used, then the security fuse is blown even if the Blow
Security Fuse enable option is disabled.
F_SETIMAGENUMBER number Choose image number between 1 and 96 from MSP Gang
Programmer internal memory.
F_INTERACTIVEMODE Switch to Interactive mode.
NOTE: The execution result can be saved in the result file. Contents of the file can be used by the
application software if required. The result can be saved in the new file or append to the
existing file. Following script line commands can be used for specifying the result file:
F_NEWRESULTFILENAME Provide a full path and name of the result file.
F_APPENDRESULTFILENAME Provide a full path and name of the file where the result should be
appended.
F_COMMENTTOFILE Add a comment at the beginning of the result stream.
Programming MSP Flash Devices Using the MSP Gang Programmer
www.ti.com
28
SLAU358QSeptember 2011Revised October 2019
Submit Documentation Feedback
Copyright © 2011–2019, Texas Instruments Incorporated
Operation
F_RESULTTOFILE Save result to the result file specified by F_NEWRESULTFILENAME or
F_APPENDRESULTFILENAME. The following data is saved:
Finished task mask: HHHH (16 bits task mask)
Cumulative target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Requested target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Connected target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Erased target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Blank Check target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Programmed target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Verified target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Secured target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
error_no: error number
VTIO in mV: VTio in mV
Vcc Error target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Vcc Cumulative Err mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
JTAG Init target mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Already Secured mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
Wrong MCU ID mask: HH (8 bits target mask - 0x01-target-1,.. 0x80-target-8);
TRACEOFF Disable tracing.
TRACEON Enable tracing and log to the Trace-Scr.txt file in the current working directory. This option is
useful for debugging. The trace file contains the sequence of all executed commands from the script file
annotated with line numbers. Line numbers are counted without empty lines and without lines containing
only comments.
END End of script.