03238396-01-01 High Flow Vacuum (TQ).pdf - 第10页
3 SAFETY 3.2 VACUUM PUMP CHARACTERISTICS 10 STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020 3.2 VACUUM PUMP CHARACTERISTICS Vacuum Pump Characteristics: Model Voltage/Frequency CFM @ 0“ S.P. Cutoff S.P Approximate Weight…

3 SAFETY
3.1 SAFETY NOTICES
STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020 9
3
SAFETY
3.1 SAFETY NOTICES
Safety notices in the form of WARNING, CAUTION and MANDATORY labels are placed on the
equipment and notices are posted throughout the associated documentation to alert the operator/
maintainer to possible hazards which may cause physical injury or equipment damage.
3.1.1 Warning Notices
Warning notices draw the attention of users/maintainers to a potentially hazardous situation which,
if not avoided, could result in death or serious injury. The following graphics display a warning label
that is displayed in the documentation:
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
3.1.2 Mandatory Notices
Mandatory notices draw the attention of users/maintainers to the prescribed behavior to be ad-
hered whilst engaged in this activity. The following graphics display the mandatory labels that are
displayed in the documentation:
MANDATORY
TOXIC SUBSTANCES MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC SUBSTANCES MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
3.1.3 Caution Notices
Caution notices draw the attention of users/maintainers to a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury or damage to the equipment. The following
graphic displays the caution label displayed in the printer documentation.
CAUTION
RECOMMENDED SOLVENTS. ANY SOLVENTS USED MUST COMPLY WITH
LOCAL ENVIRONMENTAL GUIDELINES. ASM RECOMMEND USING
SOLVENTS THAT ARE ENVIRONMENTALLY FRIENDLY, IE CFC FREE AND
WATER BASED. SOLVENTS USED MUST HAVE FAST EVAPORATION RATES
AND FLASHPOINT SPECIFICATIONS GREATER THAN 39°C.

3 SAFETY
3.2 VACUUM PUMP CHARACTERISTICS
10 STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020
3.2 VACUUM PUMP CHARACTERISTICS
Vacuum Pump Characteristics:
Model Voltage/Frequency CFM
@ 0“ S.P.
Cutoff
S.P
Approximate Weight
LBS Kg
K2BR125 230Vac/50Hz* 265 7.5 19 8.6
*230V +/- 10%

4 GLOSSARY OF TERMS
4.1 GLOSSARY
STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020 11
4
GLOSSARY OF TERMS
4.1 GLOSSARY
Term Definition
Vacuum Pump Enable Controller (VPEC) A unit that houses contactors and fused circuits which
control the switching of power to the pump.
ESIO An assembly that provides inputs and outputs to the
system sensors and the VPEC.
Diverter Valve Assembly that diverts vacuum either into the tooling or
vents it to atmosphere.
Flow Controller A manually operated valve that is used to control the
flow rate of the vacuum to the tooling plate.
Tooling Plate The plate that sits on top of the modified tabletop. It
has channels cut into its base to direct the vacuum to
the table tooling.