6 USER GUIDE
6.1 SETUP PROCEDURES
42 STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020
6.1.2 Product Changeover
NOTE
Customer’s requiring tooling design or manufacture assistance should contact ASM-DEK on:
tooling.uk@asmpt.com
1. On the HMI select Changeover from the system Menu drop-down.
2. Select the new product from the list. If the list is large, use the search function to locate the
product to load.
NOTE
Ensure that the correct product is loaded e.g. a top mounted or bottom mounted board.
3. Select Continue.
4. Select Carriage To Rear.
5. Open the cover and remove any non-reusable items (for the new product: squeegees, mater-
ial, support tooling etc.).
6. Load the new product consumables and place the tooling.
7. Select Continue.
8. Select items from the dropdown menu for each category:
– Support
– Squeegees
– Stencil
– Material
9. Close the cover.
10. Press the System button.
11. Select Manage Printer Setup.
12. Select Check Tooling.
13. Select Switch On High Flow Vacuum.
NOTE
At initialization, the presence of High Flow Vacuum is checked. However, it needs to be set for
each product.
14. Select Under Clearance. With HFV fitted the maximum allowable under clearance is 14mm.
Ensure that the setting is 14mm.
15. Select Exit.
16. Select Manage Printer Setup.
17. Select Check Alignment.
18. Select Load Stencil.
19. Open the cover.
20. Load the stencil.
21. Close the cover.
22. Press the System button.
23. Select Load Board.
24. Place a board to the input conveyor.
25. Select View Alignment.
26. Select Print Gap.
27. Set a print gap between the stencil and the board.
28. Select Accept.
29. Select Print Single Board.
30. Remove the board from the downline conveyor.
31. Select Exit.
32. Select Exit.

6 USER GUIDE
6.1 SETUP PROCEDURES
STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020 43
33. Select Complete.
34. Select the Adjust tab.
35. Select Board Limit.
36. Set the board limit to 5.
37. Select Accept.
38. In the Information bar, the information posted is: Adjust Parameters Modified. Select Save.
39. Select the Status Tab. Provided the printer is ready to accept and print some test boards
(print medium/product available) the printer is ready for printing.
40. Select Print.
6.1.3 Machine Set Up
There are no user parameters in Machine Setup that relate specifically to High Flow Vacuum set
up. The vacuum can be switched ON or OFF in: Menu/Manage Printer Setup/Check Tooling.

6 USER GUIDE
6.2 ERROR MESSAGES AND INDICATORS
44 STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020
6.2 ERROR MESSAGES AND INDICATORS
6.2.1 Vacuum Error Handling
Provided the High Flow Vacuum Check parameter (system Menu/Service/Machine Setup) has
been enabled the system reports on any vacuum problems.
On error, the user is presented with the following recovery options:
●
Retry- to repeat the vacuum check
●
Open Cover Commands: open the printhead cover- check for obstructions
●
Cancel-the print operation is stopped
●
Check the vacuum thresholds