6 USER GUIDE
6.2 ERROR MESSAGES AND INDICATORS
44 STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020
6.2 ERROR MESSAGES AND INDICATORS
6.2.1 Vacuum Error Handling
Provided the High Flow Vacuum Check parameter (system Menu/Service/Machine Setup) has
been enabled the system reports on any vacuum problems.
On error, the user is presented with the following recovery options:
●
Retry- to repeat the vacuum check
●
Open Cover Commands: open the printhead cover- check for obstructions
●
Cancel-the print operation is stopped
●
Check the vacuum thresholds
6 USER GUIDE
6.3 DIAGNOSTICS
STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020 45
6.3 DIAGNOSTICS
The diagnostic is accessed via:
1. On the HMI select Menu button.
2. Select Service.
3. Select Diagnostics.
4. Select Confirm.
The features of the page are:
– The status of the HFV Table Present (fitted or not fitted) is shown by indicator
– The status of the HFV Diverter Valve Actuated (Extended) is shown by indicator
– The status of the HFV Diverter Valve Retracted is shown by indicator
5. Select Table And Conveyor Lift.
The features of the page are:
– Switch Off HFV Pump - the system vacuum can be switched on or off
– Retract HFV Diverter valve – switches the valve to its retracted state
– The status of the HFV Table Present (fitted or not fitted) is shown by indicator
– The status of the HFV Diverter Valve Actuated (Extended) is shown by indicator
– The status of the HFV Diverter Valve Retracted is shown by indicator
– Cycle Tables. This switch cycles the table movements for several cycles as set in the
Number of Cycles parameter. The table lifts from Home to Print Height, pausing at Trans-
port Height and Vision Height
– Individual table height commands: Provides table movements to Print, Vision, Clamp,
Transport and Home heights
– Reset Axes Table command is reserved for Dual Table Mode
6. Select Exit.
7. Select Accept.
6 USER GUIDE
6.3 DIAGNOSTICS
46 STANDALONE MANUAL HIGH FLOW VACUUM (TQ) 12/2020