00196433-02_AI_Vakuumpumpe_X-Serie_70XDE+EN.pdf - 第110页
Assembly instructions: Vacuum pump for SIPLACE X-se ries 04/2009 Edition 110 : Close the covers on the extension kit s. : Position the vacuum pump – for X2/X3/X4 at location 1/3 in the area beneath the nozzle changer or …

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
109
: Screw the filter cartridge onto the vacuum pump (see photograph below).
: Attach the hose to the output on the side of the filter
cartridge and fix the hose using the “Hose
clip DIN 3017 NW 32 - 50” (item no.: 00363127-xx).
Attach the hose and fix in place
Filter cartridge
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
110
: Close the covers on the extension kits.
: Position the vacuum pump
– for
X2/X3/X4 at location 1/3 in the area beneath the nozzle changer or component trolley
docking un
it
– for X4I in front of the extension kit at locations 2 and 4.
Position
for X4I
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
111
2.9 Conversion for C&P20
2
The TwinHead and CPP head are not vacuum pump-compatible. The air supply for the gantry con-
cerned must not be converted for vacuum operation. If the compressed air supply for this head is
con
verted to vacuum operation, the return cylinder cannot move out and the Z axis thus remains
in the top position. 2
2
If a gantry is converted from C&P to TwinHead or CPP head, the original compressed air supply
must be restored for this gantry. All the modules for this gantry must be refitted.
Partial conversion of the pneumatic unit, for example, can lead to
serious faults in the placement
machine in compressed air operation because the gantry hoses are detached (additional hoses
for vacuum). 2
2
If a gantry with TwinHead is converted to C&P vacuum operation, the vacuum operation must be
retrofitted for this gantry.
If a C&P head that has been converted to vacuum oper
ation is used on a gantry with compressed
air, the silicone hoses may become detached from the segments, leading to serious damage to
the head. 2