00196433-02_AI_Vakuumpumpe_X-Serie_70XDE+EN.pdf - 第81页

Assembly instructions: Vacuum pump for SIPLACE X-series 04/2009 Edition 81 2.8.2 Gantries 2 The conversion of a distributor for placemen t heads to vacuum pump oper ation is illustrated be - low . 2 2 Fig. 2.8 - 6 V acuu…

100%1 / 128
Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
80
: Pull the hoses down so you can see the labeling.
Fig. 2.8 - 4 Labeling on the hoses (in this case for gantry 3+4)
Fig. 2.8 - 5 Converted pneumatic distributor for gantry 1+2 (opposite side)
: Attach the hoses to the gantry distributor – according to the labeling and machine configuration
(for both gantry 1+2 and gantry 3+4).
Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
81
2.8.2 Gantries
2
The conversion of a distributor for placement heads to vacuum pump operation is illustrated be-
low. 2
2
Fig. 2.8 - 6 Vacuum connection points on gantry 1+3 (initial state)
2
Fig. 2.8 - 7 Hose connection, cable and hose carrier for gantry 1+3
Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
82
Fig. 2.8 - 8 Vacuum connection points on gantry 2+4 (initial state)
Fig. 2.8 - 9 Hose connection, cable and hose carrier for gantry 2+4
2