00196433-02_AI_Vakuumpumpe_X-Serie_70XDE+EN.pdf - 第78页
Assembly instructions: Vacuum pump for SIPLACE X-se ries 04/2009 Edition 78 : Open the door to the power supply (where you will find the connections for gant ry 1 and 2) Fig. 2.8 - 2 Gantr y distr ibutor on power supply …

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
77
2
2
In the rest of these instructions, the conversion is explained with reference to versions before se-
rial number D-001. 2
Air connections for machines with serial number B-079
2
Fig. 2.8 - 1 Gantry distributor on pneumatic side (with blanking plugs for gantry 3+4, initial state)

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
78
: Open the door to the power supply
(where you will find the connections for gantry 1 and 2)
Fig. 2.8 - 2 Gantry distributor on power supply side (with blanking plugs for gantry 1+2, initial state)
: Close the compressed air main stop valve.
: Close the stop valve for the placement machine.
: Wait until the pressure has dissipated.

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
79
Remove the following blanking plugs according to the gantry configuration: 2
2
A gantry with TwinHead and CPP head cannot be converted. Leave the blanking plugs for the rel-
evant gantry in the distributor. 2
2
Machines with serial number B-079 2
– X2: Plug for gantry 1 (power supply side)
and gantry 3 (air pneumatic side)
– X3: Plug for gantry 1 + 2 (power supply side) and gantry 3 (air pneumatic side)
– X4: Plug for gantry 1 + 2 (power supply side) and gantry 3 + 4 (air pneumatic side)
Ma
chines
with serial number D-001 (pneumatic side, gantry 1 - 4) 2
: On
ly set up those gantries that you want to operate with the vacuum.
2
If you convert the wrong gantry, there is a risk of damaging the placement head. 2
2
2
: Press the blue rings (see Fig. 2.8 - 2) down axially and remove the relevant blanking plugs.
Fig. 2.8 - 3 Factory-fitted hoses (in this case for gantry 1+2)