00196433-02_AI_Vakuumpumpe_X-Serie_70XDE+EN.pdf - 第118页
Assembly instructions: Vacuum pump for SIPLACE X-se ries 04/2009 Edition 118 2.10 Converting the C&P 6/12 Fig. 2.10 - 1 C&P12 with compressed air (initial state) 2 2 BEFORE starting any work, shu t down the opera…

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
117
Fig. 2.9 - 6 C&P20 with cover for the vacuum
: Screw the cover (03046347-) hand-tight onto the “orifice ring C&P20”.
2

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
118
2.10 Converting the C&P 6/12
Fig. 2.10 - 1 C&P12 with compressed air (initial state)
2
2
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed a
ir unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
2

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
119
Fig. 2.10 - 2 Connections on the C&P12 with compressed air operation (initial state)
2
: Replace the old vacuum generator with the “Vacuum generator for vacuum pump DLM2”
(03012076-)
2
2