00196433-02_AI_Vakuumpumpe_X-Serie_70XDE+EN.pdf - 第69页
Assembly instructions: Vacuum pump for SIPLACE X-series 04/2009 Edition 69 2.4 Safety instructions WA R N I N G The safety instructions from th e “Operationa l safety” chapter of the user man ual and servicing in - struc…

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
68
2.2 Requirements
The requirements for assembly are: 2
– Machine series from no. B-079 with vacuum-compatible cable and hose carrier:
● 03022236-xx Cable and hose carrier for SIPLACE X-series 1G
● 03022237-xx Cable and hose carrier for SIPLACE X-series 2G O
● 03021065-xx Cable and hose carrier for SIPLACE X-series 2G E
● 03050655-xx (Spread Spectrum)
● 03050817-xx (Spread Spectrum)
● 03050934-xx (Spread Spectrum)
● The X-4I can generally be converted.
– C&P20 placement head (item no.: 03008827-
03
– CP20A placement head (item no.: 03062095-xx)
2
2
The SIPLACE X4I can generally be converted. 2
It is not possible to convert placement machines with serial numbers less than B079. 2
2
2.3 Tools required
– Fork wrench, size 10
– Set of hexagon socket spanners
– Set of Phillips screwdrivers
– Set of diagonal cutters
– Tubing nippers
– Release tool for Q8 (item no. 03047090-xx)
2

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
69
2.4 Safety instructions
WARNING
The safety instructions from the “Operationa
l safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with main power voltage.
Consequently parts of these systems carry dangerous voltage
s! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or
severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly,
then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
ba
se and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the
linear motors, as described
in detail in the “Special safety instructions for working in the vicinity of strong magnetic fields”
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other st
andards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages
in the Operational Safety chapter.
Follow the ESD regulations as described in the operation
al safety section of the operating
instructions.
During the assembly, always secure the machine to prevent access by other people and to pre-
vent it being switched on again. The procedure is described in the “Lock out and tag out proce-
dure ” section of the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized a
nd trained personnel.
2
2
2.4.1 Definitions
2
Please note 2
2
2
2
Caution 2

Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
70
2.4.2 Vacuum pump safety instructions
The manufacturer's safety instructions and, in particular, all the installation and start-up instruc-
tions must be followed for the vacuum pump, in addition to the safety instructions in Section 2.4.2
The placement machine and thus the vacuum pump should not be switched off and on again in
quick succession a
s this can greatly shorten the service life of the pump. 2
Switching the vacuum pump off and on for longer production stoppages, for example, is monitored
by the placement mach
ine. 2
2.4.3 ESD safety
2
Follow the ESD safety rules for the C&P placement head.
2
2