Chapter 1
This Chapter describes the work environment and working tools for the maintenance of
the machine.
Conditions for Maintenance
Multi-Functional Placer
STM1-S Maintenance Handbook
1-5
Common Working Procedure before Maintenance
1. Power supply procedure
Step 1.
Main Switch On
- Power supply turned off - Power supply turned on
2. Home
Step 1.
Press the machine's 'Ready' button
1
Step 2.
Perform homing by clicking the 'Start Home' icon
2
When the machine is in 'Ready' state, it can be returned to the
origin.(homing)
Common Working Procedure before Maintenance

Chapter 1
This Chapter describes the work environment and working tools for the maintenance of
the machine.
Conditions for Maintenance
Multi-Functional Placer
STM1-S Maintenance Handbook
1-6
Common Working Procedure before Maintenance
Conditions for Maintenance
3. Releasing 'Emergency Stop' mode
Step 1.
Press the 'EMG' button
Step 2.
Press the 'STOP' button
Step 3.
Press the 'RESET' button
Step 4.
Press the 'READY' button
Warning
Perform checking with the power supply to the motor cut off
without fail.

Chapter 1
This Chapter describes the work environment and working tools for the maintenance of
the machine.
Conditions for Maintenance
Multi-Functional Placer
STM1-S Maintenance Handbook
1-7
Working Environment and Condition
Requirements for air pressure
DEF. DESCRIPTION
Primary pressure 0.5~0.7 Mpa (5.0 ~ 7.0 kgf/cm²) (Blower 3400 mmAq)
Secondary
pressure
0.45~0.55 Mpa (4.5 ~ 5.5 kgf/cm²)
Air Consumption Maximum 350 Nℓ/min
( When using an IONIZER option, air consumption will be
increased by 360Nℓ )
Environmental conditions
DEF. DESCRIPTION
During
operation
Temperature 10℃ ~ 35℃ (20℃ ~ 28℃)
Humidity
30%~80%RH (non-condensation state)
Less than 70% RH (More than 30℃, non-
condensation state)
During
shipment or
storage (in
states other
than during
operation)
Temperature -10℃ ~ 60℃
Humidity
10%RH ~ 90% RH (non-condensation state)
More than35℃ (Less tha wet-bulb temperature
35℃, non-condensation state)
Power requirements
DEF. DESCRIPTION Notes
Capacity 3.5 KVA Blower 11KVA
Frequancy 50/60Hz
Phase 3 Phase
Connection Y-Y
Rated Primary Voltage AC200V±10%
AC208V±10%
AC220V±10%
AC240V±10%
AC380V±10%
AC415V±10%
Power consumption of the
apparatus as a whole
4.5 KVA(Max)
Warning
If unspecified voltage is used or power input is changed
improperly, fire could occur and a death from electric shock could
occur.
Change of power input must be done by a trained repair and
maintenance operator or our authorized C/S personnel.
Working Environment and Condition