STM1-S_SDV_Maintenance(Eng_Ver1).pdf - 第48页
W ee kly Inspe ction Chap ter 4 Multi -Func tional Placer ST M1-S M ain ten an ce Ha nd bo ok 4-5 Cleaning the conveyor chamber T ool for M aintenanc e cloth Measures Step 1. Pre ss th e 'STO P' a nd 'R ES…

Weekly Inspection
Chapter 4
Multi-Functional Placer
STM1-S Maintenance Handbook
4-4
Checking and Replacing Head Vacuum Filter
Weekly Inspection
Step 5.
Replace the vacuum filter
Step 6.
Release the emergency stop as described in "Releasing
'Emergency Stop' mode" on page 1-6 and perform the
operation again.
Caution
Check the vacuum filter every week and replace it within at least 6
months to ensure the vacuum for part pickup is generated properly.
Caution
It is recommended that the solenoid valve, which is a consumable
product, is replaced every two years to ensure stable operation.

Weekly Inspection
Chapter 4
Multi-Functional Placer
STM1-S Maintenance Handbook
4-5
Cleaning the conveyor chamber
Tool for Maintenance
cloth
Measures
Step 1.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 2.
Shut the main pneumatic pressure supplied to the
machine.
Step 3.
BELT TENSION SOL in IO status dialog box is changed
to Off.
Cleaning the conveyor chamber
(Time required: 15min / No. W-3)

Weekly Inspection
Chapter 4
Multi-Functional Placer
STM1-S Maintenance Handbook
4-6
Cleaning the conveyor chamber
Weekly Inspection
Step 4.
After the handler stops, a door will open.
Step 5.
While holding the belt up, clean the Chamber floor with
a cloth.
2
1