Yearly Inspection and Appendix
Chapter 6
Multi-Functional Placer
STM1-S Maintenance Handbook
6-7
Replace the Ring blower fuse
Step 7.
Pull the Fuse case to detach.
Step 8.
Replace the fuse with a new one.
Caution
When assembling the Fuse case, be careful to ensure the polarity
is correct.

Yearly Inspection and Appendix
Chapter 6
Multi-Functional Placer
STM1-S Maintenance Handbook
6-8
Ring blower inverter setup
Yearly Inspection and Appendix
Ring blower inverter setup
Measures
Step 1.
Refer to the following configuration table for Inverter,
and modify the configuration values of the Inverter.
Function Function name Setup range Initial Setup Modified value
A01 Frequency Command method (various
speed 0 speed command modification)
0-Main body volume
1-Input from control circuit terminal
2-Standard operator
3-Remote operator(1st communication-RJ45)
4-Remote operator(2nd communication-terminal block)"
1 0 X
(Time required: 15min / No. E-3)

Yearly Inspection and Appendix
Chapter 6
Multi-Functional Placer
STM1-S Maintenance Handbook
6-9
Ring blower inverter setup
C03 Intelligent input terminal 3 is set. "0-FW(Forward operation command)
1-RV(Reverse operation command)
2-CF1(variable speed 1)
3-CF2(variable speed 2)
4-CF3(variable speed 3)
5-CF4(variable speed 4)
6-JG(Jog operation command)
8-2CH(2-step accelerate/decelerate command)
9-FRS(Free-run command)
10-EXT(External trip)t
11-USP(Unattended Start Protection)
12-SFT(Soft lock)
13-AT(Analog input voltage/current switchover)
14-RS(Reset)
15-STA(Start)
16-STP(Maintain)
17-F/R(Forward/reverse)
18-UP(Remote control UP)
19-DOWN(Remote control DOWN)
20-O/R(Operate/remote switchover)
21-T/R(Terminal block/remote switchover)
22-PIDIR(PID integration value reset)
23-PIDD(PID Disable)"
2 10 X