ST M1-S M ain ten an ce Ha nd bo ok 3-3 Chap ter 3 Daily Inspe ction Multi -Func tional Placer Checking and cleaning the nozzle Caution Wipe the cleaning liquid on the nozzle using a clean cloth, ensuring none remains on…

100%1 / 84
STM1-S Maintenance Handbook
3-2
Chapter 3
Daily Inspection
Multi-Functional Placer
Checking and cleaning the nozzle
Daily Inspection
Nozzle Insertion hole
Nozzle net
Step 7.
Clean the nozzles with the ultrasonic cleaner and inject
air into the nozzle holes using an air gun.
Air gun
Nozzle
hole
Pneumatic air
spraying direction
Caution
Using the air gun without putting on goggles may cause injury to
the eyes of the operator. Be sure to wear goggles when using the
air gun.
Step 8.
When foreign materials (solder paste, etc.) remain inside
the nozzle, pass a pin through the nozzle hole and clean
it with an air gun.
Residual foreign material
(solder paste, etc.)
Inner bore
penetrating pin
Pin insert
direction
Air gun
Pneumatic
air spraying
direction
If the foreign materials (solder paste, etc.) have not been removed, repeat
cleaning once more.
STM1-S Maintenance Handbook
3-3
Chapter 3
Daily Inspection
Multi-Functional Placer
Checking and cleaning the nozzle
Caution
Wipe the cleaning liquid on the nozzle using a clean cloth, ensuring
none remains on the nozzle.
When foreign materials remain on the nozzle continuously, contact
our C/S company (STS) or local agent to solve the problem.
Use the ultrasonic cleaning machine, the clean case the Nozzle, you
will be able to improve the cleaning of the nozzle.
Step 9.
The method to clean the nozzle is as follows:
Spray the cleaning liquid recommended by us on the nozzle exterior using a spray
straw.
Clean the nozzle exterior with a clean cloth within 1 minute after spraying the
cleaning liquid.
If the foreign materials (solder paste, etc.) have not been removed, repeat
cleaning once more.
Step 10.
Release the emergency stop as described in "Releasing
'Emergency Stop' mode" on page 1-6 and perform the
operation again.
STM1-S Maintenance Handbook
3-4
Chapter 3
Daily Inspection
Multi-Functional Placer
Cleaning feeder and feeder base
Daily Inspection
Cleaning the feeder and feeder base can prevent feeder installation error and
defective contact of the connector.
Tool for Maintenance
Brush
Measures
Step 1.
Move the X Frame to rear by referring to "Backward
movement of the X-frame" on page 1-4.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 3.
Remove the feeder from the feeder base.
Pull the grip back
Remove the cover tape
Remove the feeder
Cleaning feeder and feeder base
(Time required: 10min / No. D-2)