STM1-S_SDV_Maintenance(Eng_Ver1).pdf - 第62页

Mon thly Inspe ction Chap ter 5 Multi -Func tional Placer ST M1-S M ain ten an ce Ha nd bo ok 5-1 1 Cleaning and Lubricating Y Frame LM Guide Monthly Inspe ction Step 4 . Move t he X fr ame to t he fr ont si de an d appl…

100%1 / 84
Monthly Inspection
Chapter 5
Multi-Functional Placer
STM1-S Maintenance Handbook
5-10
Cleaning and Lubricating Y Frame LM Guide
Tool for Maintenance
Ultra-fine fiber cloth, Flat Brush, Lubricator (Grease-Gun_Mg70_THK), Grease :
AFE(THK)
Measures
Step 1.
Move the X Frame to front by referring to "Forward
movement of the X-frame" on page 1-3.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 3.
Clean the LM guide rail and ball screw using an ultra fine
fiber cloth.
Cleaning and Lubricating Y Frame LM Guide
(Time required: 60min / No. M-7)
Monthly Inspection
Chapter 5
Multi-Functional Placer
STM1-S Maintenance Handbook
5-11
Cleaning and Lubricating Y Frame LM Guide
Monthly Inspection
Step 4.
Move the X frame to the front side and apply grease on
the LM Guide using a grease gun (0.5 time (apply a half
amount of grease))
Move the X Frame to the rear side and apply grease in
the same way as the front side
Caution
The designated grease must be applied using the designated
lubricator in the designated manner. Other lubricating methods are
unacceptable.
If the machine's operating environment is harsh, check its lubrication
status frequently.
Monthly Inspection
Chapter 5
Multi-Functional Placer
STM1-S Maintenance Handbook
5-12
Cleaning and Lubricating Y Frame LM Guide
Monthly Inspection
Step 5.
Move the X frames back and forth three times.
Step 6.
Release the emergency stop as described in "Releasing
'Emergency Stop' mode" on page 1-6 and perform the
operation again.