STM1-S_SDV_Maintenance(Eng_Ver1).pdf - 第84页
STM1-S Maintenance Handbook Hanwha T echwin Co., Ltd. http://smt.hanwhatechwin.com 6, Pangyo-ro 319beon-gi l, Bundang-gu, Seongnam-si, Gyeonggi-do (Post Code: 463-400) © 20 1 7 Hanwha T echwin Co.,L td.

Yearly Inspection and Appendix
Chapter 6
Multi-Functional Placer
STM1-S Maintenance Handbook
6-10
Ring blower inverter setup
Yearly Inspection and Appendix
H04 Number of motor poles is selected. 2/4/6/8 poles [P] 4 2 X
H05 Motor rated current “This value is set according to the inverter capacity.
0.1-800.0[A]"
- 17 X
F01 Output frequency selection "0.00-400.0[Hz]
For sensorless vector control, 0.00-300.0[Hz]"
0.00Hz 60 O
F02 Acceleration 1 is set. 0.1~3000[sec] 30 20 O
F03 Deceleration 1 is set. 0.1~3000[sec] 30 10 O

Yearly Inspection and Appendix
Chapter 6
Multi-Functional Placer
STM1-S Maintenance Handbook
6-11
Consumable Parts List
No Part name Part No. Module Replacement cycle Remark
1 Air Filter
Refer to Air Filter check and
replacement.
2 Mist Separator Filter
Refer to Mist Separator Filter check
and replacement.
3 Detach nozzle pad
Refer to Detach Nozzle Pad filter
check and replacement
4 Head Vacuum Filter
Refer to Head Vacuum Filter check
and replacement.
5 Detach vacuum ejector filter
Refer to Detach vacuum ejector
filter check and replacement
6 Cover Cooling Fan Filter
Cover Cooling Fan Filter cleaning
and replacement.
7 Ionizer Nozzle
Cover Cooling Fan Filter cleaning
and replacement.
8 Fuse Refer to replace fuse .
9 Ring blower fuse
Refer to replace the ring blower
fuse .
Consumable Parts List