00197728-12_IM_SE3.11_EN.pdf - 第10页

1 Introduction Installation and Configuration Guide SIPLACE Expl orer 1.3 Additional Remarks Edition 11/2020 EN 10 – The following restrictions appl y t o the SMA pages listed below , if no boards a re placed at the last…

100%1 / 90
Installation and Configuration Guide SIPLACE Explorer 1 Introduction
Edition 11/2020 EN 1.3 Additional Remarks
9
1.3 Additional Remarks
SIPLACE Explorer has the following restrictions: 1
Restriction due to NPI mode
SIPLACE Explorer is unable to use data from SIS for boards which are marked as "SA" (stand-
alone). This means that the following information is not available for boards marked with "SA":
Component name
Component shape
Feeder type
The following SMA pages show limited data due to the "Stand-alone" mode: 1
Pickup Reliability
Pickup Summary
Reject Rate
Transition Log
Factory Layout:
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment"
is installed) can monitor five production lines with up to 20 stations.
Single Line Layout
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment"
is installed) can monitor one production line with up to 7 stations.
For performance reasons, we recommend that you do not generate reports for all websites and
report types at once. Try to run the report generation at a time when there is no production op-
eration e.g. at the weekend.
The system time on the connected machines and that belonging to the SIPLACE Explorer must
be synchronized. SIPLACE machines require the installation of TimeSync, which is included
on the Support Media provided with the delivery.
There is a special OIS status model realized in SIPLACE OIS. This OIS status model is shown
in the SIPLACE Explorer status model which matches the SEMI E10 status module. This may
lead to deviations in the states and status times shown between OIS and SIPLACE Explorer.
A direct comparison is therefore not possible.
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.3 Additional Remarks Edition 11/2020 EN
10
The following restrictions apply to the SMA pages listed below, if no boards are placed at the
last station in the production line:
Machine Navigator:
OLE value will not be shown (N/A).
Overview of OLE / OEE:
Overall Line Efficiency diagram: Values for OLE, performance and availability will not be
shown correctly.
Overall Equipment Efficiency by Station diagram: station data is not shown correctly for
stations which do not place boards.
OEE Analysis:
Table: values for performance and availability will not be shown correctly for lines and sta-
tions which do not place boards.
Overall Equipment Efficiency diagram – comparison diagram: Values for OLE, perfor-
mance and availability will not be shown correctly for the line.
The name of the computer on which Tomcat is installed may not include special characters, in
particular no underscore (_). If the name does include these characters, it will not be possible
to display the website.
Installation and Configuration Guide SIPLACE Explorer 2 System Components and Configurations
Edition 11/2020 EN 2.1 Overview of System Components
11
2 System Components and
Configurations
2.1 Overview of System Components
SIPLACE Explorer can either be installed in SIPLACE LAN or distributed via SIPLACE and client
LANs. Users not wishing to install the complete SIPLACE Explorer program on one computer can
distribute the individual components among several computers. 2
The SIPLACE Explorer architecture is displayed in the following diagram: 2