4 Configuration Installation and Configuration Guide SIPLACE Exp lorer 4.2 Configuring the Factory Configuration Utility Edition 11/202 0 EN 60 4 Fig. 4 - 27 Build configuration At t his point, the application is generat…

Installation and Configuration Guide SIPLACE Explorer 4 Configuration
Edition 11/2020 EN 4.1 Standard Monitoring Application (SMA)
59
NOTE
We recommend activating this DB compression step, when the user has restored the
SIPLACE Explorer line database or has moved the raw database files to another disk or to
another computer.
With the DB compression it is possible to avoid extended access times of the websites.
The DB compression may take up to one hour, this time depends on the size of the database
and the performance of the computer. 4
If you have enabled the Backup database option, the DB backup location dialog box will
open.
4
Fig. 4 - 26 DB backup location
If enabled, before performing the compression, the system creates a backup file of the
database. Specify the folder for this file in the Folder for database backup field. Click on the
Browse ... button to select an existing folder.
Confirm your choice with OK. The DB compression will be started.
An information box will appear, showing the DB compression and the website generation.

4 Configuration Installation and Configuration Guide SIPLACE Explorer
4.2 Configuring the Factory Configuration Utility Edition 11/2020 EN
60
4
Fig. 4 - 27 Build configuration
At this point, the application is generated automatically and is loaded into SIPLACE Explorer.4
Once the website has been fully generated, click on Close. The SMA has been completed.
Click on the Exit button in the Line Configuration - Website Generation dialog box.
4.2 Configuring the Factory Configuration Utility
4.2.1 Starting the SIPLACE Factory Configuration Utility
Start the SIPLACE Factory Configuration Utility via the Programs SIPLACE Explorer
Factory Configuration Utility menu in Windows.
Or click on the Factory Configuration Utility icon on your desktop.
NOTE
Access to the Runtime Environment tools is restricted or permitted as required, by using the
SE Security Manager. For details of the relevant settings in the SE Security Manager, refer
to the Getting Started for SIPLACE Explorer. 4
The Load settings from... dialog box will open. You need to establish a connection to the
factory database, before data can be called up.

Installation and Configuration Guide SIPLACE Explorer 4 Configuration
Edition 11/2020 EN 4.2 Configuring the Factory Configuration Utility
61
4
Fig. 4 - 28 Loading settings
Enter the following information:
– MS SQL Server:port number
You can add the port number to the SQL Server instance, separated by a colon, for
example: PLK0495A\SIPLACE_2005EXPR:12345.
– Database name
– Database user
– DB password
NOTE
Click on the Browse for SQL instances icon. All SQL server instances available will be
shown in the Select SQL Server instance dialog box.
If the Select SQL Server instance dialog box shows no entries, you need to specify the SQL
server instance manually in the MS SQL Server field. 4
After entering the database access parameters, we strongly recommend that you check the
connection to the database. Click Test to check whether the connection to the database can
be established.