Installation and Configuration Guide SIPLACE Explorer 4 Configur ation Edition 11/2020 EN 4.1 Standard Monitoring Application (SMA) 3 9 4 Configuration This chapter will describe the following configurations: 4 – “S tand…

100%1 / 90
3 Installing SIPLACE Explorer Installation and Configuration Guide SIPLACE Explorer
3.6 Port Configuration after Changing Tomcat Port Number Edition 11/2020 EN
38
Installation and Configuration Guide SIPLACE Explorer 4 Configuration
Edition 11/2020 EN 4.1 Standard Monitoring Application (SMA)
39
4 Configuration
This chapter will describe the following configurations: 4
“Standard Monitoring Application (SMA)” on page 39
“Configuring the Factory Configuration Utility” on page 60
“Database Settings” on page 80
4.1 Standard Monitoring Application (SMA)
SIPLACE Explorer allows you to create custom-made applications to monitor production lines.
Standard Monitoring Application (SMA) and a set of corresponding websites are supplied with the
installation media. SMA features various web pages that capture basic production information
such as machine status and time allocation, performance, components consumption, reject rate,
etc. This section describes how you can easily customize Standard Monitoring Application for your
production line configuration. 4
4.1.1 Runtime Environment: Creating an SMA with Line Configuration
In order to create an SMA with the line configuration option, you must have SIPLACE Explorer
Runtime Environment installed on your computer. SMA creation consists of the following steps:4
Line configuration (wizard with 7 steps)
Establishing a connection to the database (wizard with 3 steps)
4 Configuration Installation and Configuration Guide SIPLACE Explorer
4.1 Standard Monitoring Application (SMA) Edition 11/2020 EN
40
4.1.1.1 Starting Line Configuration
Open Line Configuration.
Proceed by selecting Programs SIPLACE Explorer Line Configuration from the menu
in Windows or by clicking on the icon in the console. Right-click with the mouse to select
the Line Configuration menu.
When you first start the Line Configuration, the login dialog box will open. Register yourself
as a default user with "Admin" or "Operator" and leave the password field empty.
4
Fig. 4 - 1 SIPLACE Explorer login
NOTE
Access to the Runtime Environment tools is restricted or permitted as required, by using the
SE Security Manager. For details of the relevant settings in the SE Security Manager, refer
to the Getting Started for SIPLACE Explorer. 4
The Line Configuration dialog box will open. This is the first step of the line configuration
process.