00195311-0202_SM_CurrentLimiter_DE EN.pdf - 第27页

Service Manual: Replacing the inrush current limiter, SIPLACE X-series 10/2006 Edition 27 : Remove the insulation sleeving from the hexa gonal spacer at the top left. 2 2 : Unscrew the four hexagon al spacers. 2 2 Insula…

100%1 / 38
Service Manual: Replacing the inrush current limiter, SIPLACE X-series
10/2006 Edition
26
2.5 Replacing the inrush current limiter
: Loosen the four screws on the Plexiglas cover of the inrush current limiter and remove the
cover.
2
2
: Detach the 5 connectors from the inrush current limiter.
2
4 screws
5 connectors
Service Manual: Replacing the inrush current limiter, SIPLACE X-series
10/2006 Edition
27
: Remove the insulation sleeving from the hexagonal spacer at the top left.
2
2
: Unscrew the four hexagonal spacers.
2
2
Insulation
sleeving
4 hexagonal
spacers
Service Manual: Replacing the inrush current limiter, SIPLACE X-series
10/2006 Edition
28
: Remove the nut in the middle of the inrush current limiter.
2
2
: Remove the inrush current limiter.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Nut