00195311-0202_SM_CurrentLimiter_DE EN.pdf - 第31页

Service Manual: Replacing the inrush current limiter, SIPLACE X-series 10/2006 Edition 31 : Plug the connector s in line with the supply volt age: 2 2 The inrush current li mitation board must be configured in line with …

100%1 / 38
Service Manual: Replacing the inrush current limiter, SIPLACE X-series
10/2006 Edition
30
: Attach the new inrush current limiter.
2
2
: Screw the nut in the middle of the inrush current limiter.
: Screw on the old or the new (connected) hexagonal spacers.
2
Hexagonal spacers
Service Manual: Replacing the inrush current limiter, SIPLACE X-series
10/2006 Edition
31
: Plug the connectors in line with the supply voltage:
2
2
The inrush current limitation board must be configured in line with the supply voltage. This is per-
formed with the help of plug-in jumpers on the inrush current limitation board. 2
: Check the jumper assignements and correct these, where necessary.
2
2
2
2
2
2
2
2
2
X1, X2, X3: Plug-in jumper to configure the
inrush current limitation
Service Manual: Replacing the inrush current limiter, SIPLACE X-series
10/2006 Edition
32
: Push the old or the new, longer insulation sleeving from the retrofit kit onto the hexagonal
spacer at the top left.
2
2
: Attach the new grid cover.
Screw it in place with four screws. The screw holes are located between the grid openings.
2
2