TRS GEM Manual for Intel Ver 1.1.pdf - 第111页

GEM Manual for DEK P rinters Equipment Variables Issue 1.1 March 20th, 2014 Page 111 of 152 Page 111 of 152 7.4.1 Limit List The L imit Set Values are held in a list that is structured as follows: <L imit List> : S…

100%1 / 152
GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 110 of 152 Page 110 of 152
Name
DVID
Limits
Monitor
Description
Type
Value Range
screen_fiducial_2_score
2025
Yes
The acceptance score of screen
fiducial 2.
U4
0-1000
screen_fiducial_3_score
2026
Yes
The acceptance score of screen
fiducial 3.
3 fiducial mode must be selected.
U4
0-1000
LimitVariable
2027
No
This variable contains the VID for
the variable whose value changed
monitoring zones.
U4
See list of VID’s for limits
monitoring.
EventLimit
2028
No
This variable contains the
LIMITID of the limit reached or
crossed by LimitVariable. Since
multiple zone transitions for a
variable may occur simultaneously,
EventLimit has been defined to
allow for a list of LIMITIDs.
List of
U1
1-7
TransitionType
2029
No
This variable defines the direction
of the zone transition that has
occurred.
B
1 byte
0 = Transition from lower
zone to upper zone.
1 = Transition from upper
zone to lower zone.
RemoteBarCode
2030
No
Product bar code string provided
by the serial bar code reader.
The default is “NO CODE”.
A32
Up to a 32 character string.
The actual length is
determined by the barcode.
ProflowPastePressure
2031
Yes
Actual Paste Pressure used by the
Proflow paste mechanism.
F8
0-20 Kg
Reserved
2032
No
Not used by the 265.
Traceability Data
2033
No
List of traceability data for the last
processed product.
Variable
See <Traceability Data>
Failed verification item
2034
No
List of the items that last failed
verification
Variable
See <Failed Verification
Items>
Reserved
2083
No
Reserved
2084
No
Reserved
2085
No
Not used.
front_print_speed
2086
Yes
Speed measured during the last
front print stroke.
F8
2-150 mm/s
rear_print_speed
2087
Yes
Speed measured during the last rear
print stroke.
F8
2-150 mm/s
Modified Parameters
2088
No
This variable contains the
parameter ID, name, old value and
new value for the parameters
whose value changed at instrument.
Modifie
d
Paramet
er List
See <Modified Parameter
List>
PrintDeposits
2090
No
This variable contains the number
of print deposits during a print
cycle.
U1
1-10
PrintSpeedDeposit1 to
PrintSpeedDeposit10
2091 to
2100
No
These variables contain the print
stroke speeds for their
corresponding print deposit during
a print cycle.
F8
2-300 mm/s
CleanRate1
2151
No
This variable contains the 1st rate
at which a clean takes place during
a print cycle.
U4
0-100
CleanRate2
2152
No
This variable contains the 2nd rate
at which a clean takes place during
a print cycle.
U4
0-100
LastCleanType
2153
No
This variable contains the last clean
type that took place.
A32
Up to a 32 character string
representing the clean type.
GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 111 of 152 Page 111 of 152
7.4.1 Limit List
The Limit Set Values are held in a list that is structured as follows:
<Limit List>:
Structure: L, m ; m = Number of Limit sets
; with SPC output enabled.
1. L, 28 ; First Limit Set
1. Limit Blockage Ave ;Type F4
2. Limit Blockage Max ;Type F4
3. Limit blockage Max Site ID ;Type A20
4. Limit Blockage Min ;Type F4
5. Limit blockage Max Site ID ;Type A20
6. Limit Paste Ave ;Type F4
7. Limit Paste Max ;Type F4
8. Limit paste Max Site ID ;Type A20
9. Limit Paste Min ;Type F4
10. Limit paste Min Site ID ;Type A20
11. Limit Volume Ave ;Type F4
12. Limit Volume Max ;Type F4
13. Limit volume Max Site ID ;Type A20
14. Limit Volume Min ;Type F4
15. Limit volume Min Site ID ;Type A20
16. Limit Print X Ave ;Type F8
17. Limit Print X Max ;Type F8
18. Limit print X Max Site ID ;Type A20
19. Limit Print X Min ;Type F8
20. Limit print X Min Site ID ;Type A20
21. Limit Print Y Ave ;Type F8
22. Limit Print Y Max ;Type F8
23. Limit print Y Max Site ID ;Type A20
24. Limit Print Y Min ;Type F8
25. Limit print Y Min Site ID ;Type A20
26. Limit Smear ;Type F8
27. Limit Bridging ;Type F8
28. Limit ID ;Type A20
.
. ; all elements of the list are identically
m. ; structured
GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 112 of 152 Page 112 of 152
The items in the list are as follows:
No.
Item
Limits
Monitor
Description
Type
Range
1
Limit Blockage Ave
Yes
Stencil average percentage aperture blockage
for limit set.
F4
0-100 %
2
Limit Blockage Max
Yes
Stencil maximum percentage aperture blockage
for limit set.
F4
0-100 %
3
Limit Blockage Max Site ID
No
Site ID that generated the maximum blockage
for limit set.
A20
Up to 20
characters max.
4
Limit Blockage Min
Yes
Stencil minimum percentage aperture blockage
for limit set.
F4
0-100 %
5
Limit Blockage Max Site ID
No
Site ID that generated the minimum blockage
for limit set.
A20
Up to 20
characters max.
6
Limit Paste Ave
Yes
Average paste present for limit set.
F4
0-100 %
7
Limit Paste Max
Yes
Maximum paste present for limit set.
F4
0-100 %
8
Limit Paste Max Site ID
No
Site ID that generated the maximum paste
present for limit set.
A20
Up to 20
characters max.
9
Limit Paste Min
Yes
Minimum paste present for limit set.
F4
0-100 %
10
Limit Paste Min Site ID
No
Site ID that generated the minimum paste
present for limit set.
A20
Up to 20
characters max.
11
Limit Volume Ave
Yes
Average paste volume for limit set.
F4
0-100 %
12
Limit Volume Max
Yes
Maximum paste volume for limit set.
F4
0-100 %
13
Limit Volume Max Site ID
No
Site ID that generated the maximum volume for
limit set.
A20
Up to 20
characters max.
14
Limit Volume Min
Yes
Minimum paste volume for limit set.
F4
0-100%
15
Limit Volume Min Site ID
No
Site ID that generated the minimum volume for
limit set.
A20
Up to 20
characters max.
16
Limit Print X Ave
Yes
Average paste-pad X error for limit set.
F8
1 mm
17
Limit Print X Max
Yes
Maximum paste-pad X error for limit set.
F8
1 mm
18
Limit Print X Max Site ID
No
Site ID that generated the maximum X error for
limit set.
A20
Up to 20
characters max.
19
Limit Print X Min
Yes
Minimum paste-pad X error for limit set.
F8
1 mm
20
Limit Print X Min Site ID
No
Site ID that generated the minimum X error for
limit set.
A20
Up to 20
characters max.
21
Limit Print Y Ave
Yes
Average paste-pad Y error for limit set.
F8
1 mm
22
Limit Print Y Max
Yes
Maximum paste-pad Y error for limit set.
F8
1 mm
23
Limit Print Y Max Site ID
No
Site ID that generated the maximum Y error for
limit set.
A20
Up to 20
characters max.
24
Limit Print Y Min
Yes
Minimum paste-pad Y error for limit set.
F8
1 mm
25
Limit Print Y Min Site ID
No
Site ID that generated the minimum Y error for
limit set.
A20
Up o 20
characters max.
26
Limit Smear
Yes
Stencil paste smear area for limit set.
F8
5 sq. mm
27
Limit Bridging
Yes
Board pad bridging for limit set.
F8
1 mm
28
Limit ID
No
The limit set name.
A20
Up to 20
characters max.
Exception: A zero length list m = 0 indicates that no limit sets are enabled for SPC output.
7.4.2 Modified Parameter List
The Modified Parameter list is structured as follows:
<Modified Parameter List>:
Structure: L, m ; m = Number of Modified Parameter list
1. L,4