TRS GEM Manual for Intel Ver 1.1.pdf - 第36页

GEM Manual for DEK P rinters Capabilities Issue 1.1 March 20th, 2014 Page 36 of 152 Page 36 of 152 # Current State Trigger New Stat e Action Comm ent 7 EQUIPMENT RUNNING 1. Operato r action to select end run. 2. Batch li…

100%1 / 152
GEM Manual for DEK Printers Capabilities
Issue 1.1 March 20th, 2014 Page 35 of 152 Page 35 of 152
EQUIPMENT RUNNING - The equipment running state is active from the time process
material is loaded until another processing state is selected/instigated.
EQUIPMENT WAITING - The machine is in the equipment waiting state when the
equipment is waiting for process material to be transferred/loaded from the upline machine or is
waiting for process material to be transferred/unloaded to the downline machine. Once these
two activities have been performed, the running state is resumed unless a fault occurs.
EQUIPMENT DOWN - In the equipment down state one or other of the following sub-states
can be in operation:
A system error has occurred.
Restart from a system error once the error has cleared.
Diagnostics - whereby discrete I/O can be controlled to directly control machine movement
for debugging problems and troubleshooting. Internal machine values can be viewed and
modified. This state is active for as long as the operator requires to perform the necessary
diagnostic procedure/s.
Initial diagnostics - when powering up the machine.
EQUIPMENT MAINTENANCE - The equipment maintenance state is active when
housekeeping and calibration procedures are in operation. This state is active for as long as the
operator requires to perform the necessary procedure/s.
Transition Table:
#
Current State
Trigger
New State
Action
Comment
1
EQUIPMENT
RECOVERY
All software and hardware
initialisation has been
completed.
EQUIPMENT
READY
None
Machine has been restored to
its ready condition following
from an error situation.
2
EQUIPMENT
READY
1. Operator action to select
run mode.
2. Host action to select run
mode.
EQUIPMENT
RUNNING
None
Equipment is now printing
3
EQUIPMENT
RUNNING
1. Paste dispense cycle.
2. Clean screen cycle.
EQUIPMENT
SETUP
None
This covers automatic or
manual paste dispenses and
automatic screen clean cycles
4
EQUIPMENT
SETUP
Completion of:
1. Paste dispense cycle.
2. Clean screen cycle.
EQUIPMENT
RUNNING
None
State subsequent to the state
above when the function is
complete.
5
EQUIPMENT
RUNNING
1. Process material being
loaded from the upline
machine.
2. Process material being
unloaded to the downline
machine.
EQUIPMENT
WAITING
None
Printer is in this state when
waiting to unload or load
boards to/from the external
machine.
6
EQUIPMENT
WAITING
1. Process material
successfully loaded from the
upline machine
2. Process material
successfully unloaded to the
downline machine and next
process material successfully
loaded from the upline
machine.
EQUIPMENT
RUNNING
None
Board delivered or received
to/from external machine.
GEM Manual for DEK Printers Capabilities
Issue 1.1 March 20th, 2014 Page 36 of 152 Page 36 of 152
#
Current State
Trigger
New State
Action
Comment
7
EQUIPMENT
RUNNING
1. Operator action to select
end run.
2. Batch limit complete.
3. Host action to select end
run.
EQUIPMENT
READY
None
Batch complete.
8
EQUIPMENT
READY
1. Head opening/open.
2. Paste dispense cycle.
3. Clean screen cycle.
4. Screen change.
5. Tooling change.
6. Pressure readings being
taken.
7. Operator action to select
Setup mode.
EQUIPMENT
SETUP
None
Any machine setup selected.
9
EQUIPMENT
READY
Operator selects
maintenance key.
EQUIPMENT
MAINTENANCE
None
None
10
EQUIPMENT
SETUP
Completion of :
1. Head closing/closed.
2. Clean screen cycle.
3. Paste dispense cycle.
4. Operator action to exit
Setup mode.
EQUIPMENT
READY
None
Follow on from state 8 when
function is complete.
11
EQUIPMENT
MAINTENANCE
Operator selects exit from
maintenance mode.
EQUIPMENT
READY
NONE
Follow on from state 9 when
maintenance complete.
12
EQUIPMENT
SETUP
1. Operator selects
diagnostics by using mode
change.
2. A system error occurring.
3. Restart from a system
error.
4. Initial diagnostics, when
powering-up the machine.
EQUIPMENT
DOWN
Error
notification
or
diagnostics
entered.
None
13
EQUIPMENT
WAITING
14
EQUIPMENT
RUNNING
15
EQUIPMENT
READY
16
EQUIPMENT
MAINTENANCE
17
EQUIPMENT
DOWN
1. Operator selects recover
action.
2. Restart from a system
error complete.
EQUIPMENT
RECOVER
None
Any recovery from the
Equipment Down state
18
EQUIPMENT
MAINTENANCE
1. User selects ‘Machine
Setup’ button
EQUIPMENT
SETUP
None
Move from Maintenance to
Setup screen
19
EQUIPMENT
SETUP
1. Having come from
Maintenance page (transition
18) user selects the ‘Back’
button
EQUIPMENT
MAINTENANCE
None
Move back from Setup to
Maintenance screen
GEM Manual for DEK Printers Capabilities
Issue 1.1 March 20th, 2014 Page 37 of 152 Page 37 of 152
5.5 Equipment Constants
This capability enables the host to read and set the value of the equipment constants defined in
chapter 7. For this purpose, the following functionality is provided.
Host can send a list of equipment constant identities ECID's and values ECV's.
Host can request current ECV's.
Host can request a list of EC names.
Scenarios:
Host sends equipment constants:
Comments
Host
Equipment
Comments
List of constants and values
S2F15 -->
<-- S2F16
Acknowledge
Host equipment constant request:
Comments
Host
Equipment
Comments
Request constants
S2F13 -->
<-- S2F14
List of ECID's and ECV's
Host equipment constant namelist request:
Comments
Host
Equipment
Comments
Request constant namelist
S2F29 -->
<-- S2F30
EC Name list
Operator changes equipment constant:
Comments
Host
Equipment
Comments
<-- S6F11
Equipment sends EC change event
Host Acknowledges change
S6F12 -->