GEM Manual for DEK P rinters SECS II Implementation Issue 1.1 March 20th, 2014 Page 83 of 152 Page 83 of 152 6.5 STREAM 5: E XCEPTION (A larm) REPORTING S5F1 Alarm Report Send (ARS) S5F2 Alarm Report Acknowledge (ARA) De…

100%1 / 152
GEM Manual for DEK Printers SECS II Implementation
Issue 1.1 March 20th, 2014 Page 82 of 152 Page 82 of 152
Equipment to host: S2F48
Structure:
1. L,m ;m = No. of VID’s this request.
1. L,2
1. <VID1>
2. L,p {p = 0,4}
1. <UNITS1>
2. <LIMITMIN1>
3. <LIMITMAX1>
4. L,n ;n = No. of limits defined for this VID
1. L,3
1. <LIMITID1>
2. <UPPERDB1>
3. <LOWERDB1>
.
.
n. L,3
1. <LIMITIDn>
2. <UPPERDBn>
3. <LOWERDBn>
.
.
m. L,2
1. <VIDm>
2. L,p {p = 0,4}
1. <UNITSm>
2. <LIMITMINm>
3. <LIMITMAXm>
4. L,n ;n = No. of limits defined for VIDm
1. L,3
1. <LIMITID1>
2. <UPPERDB1>
3. <LOWERDB1>
.
.
n. L,3
1. <LIMITIDn>
2. <UPPERDBn>
3. <LOWERDBn>
Exceptions:
1. A zero length list, p = 0 indicates that limits are not supported for the VID.
2. A zero-length list, n = 0 indicates no limits are currently defined for the
specified variable.
B. Equipment Initiated - Not applicable.
GEM Manual for DEK Printers SECS II Implementation
Issue 1.1 March 20th, 2014 Page 83 of 152 Page 83 of 152
6.5 STREAM 5: EXCEPTION (Alarm) REPORTING
S5F1 Alarm Report Send (ARS)
S5F2 Alarm Report Acknowledge (ARA)
Description: When the equipment detects a change in alarm state (e.g. cover open or
closed), it sends an ARS report message.
A. Host Initiated - Not applicable
B. Equipment Initiated
Equipment to host: S5F1
Structure: L,3
1. <ALCD>
2. <ALID>
3. <ALTX>
Host to equipment: S5F2
Structure: <ACKC5>
S5F3 Enable / Disable Alarm Send (EAS)
S5F4 Enable / Disable Alarm Acknowledge (EAA)
Description: The host uses this message to enable or disable the reporting of alarms.
A. Host Initiated
Host to equipment: S5F3
Structure: L,2
1. <ALED>
2. <ALID>
A zero length item for ALID means all alarms.
Host to equipment: S5F4
Structure: <ACKC5>
B. Equipment Initiated - Not applicable.
GEM Manual for DEK Printers SECS II Implementation
Issue 1.1 March 20th, 2014 Page 84 of 152 Page 84 of 152
S5F5 List Alarms Request (LAR)
S5F6 List Alarms Data (LAD)
Description: The host requests a status list of possible alarms in LAR. The list is
returned in LAD.
A. Host Initiated
Host to equipment: S5F5
Structure: <ALID1,.....,ALIDn>
Exception: If zero length item, then all possible alarms must be sent.
Equipment to Host: S5F6
Structure: L,m
1. L,3
1. <ALCD1>
2. <ALID1>
3. <ALTX1>
.
.
m. L,3
1. <ALCDm>
2. <ALIDm>
3. <ALTXm>
Exception: If m = 0 then no response is possible. If zero length ALCD or ALTX
then that value does not exist.
B. Equipment Initiated - Not applicable.
S5F7 List Enabled Alarms Request (LEAR)
S5F8 List Enabled Alarms Data (LEAD)
Description: The host requests a status list of enabled alarms in LEAR. The list is
returned in LEAD.
A. Host Initiated
Host to equipment: S5F7
Structure: Header only
Equipment to Host: S5F8
Structure: Same as S5F6, but only enabled alarms are included in the list.
B. Equipment Initiated - Not applicable.