2 Circuit Diagr ams 60 0033681 2-020102 TD3 Power suppl y structur e (Sh. 1 of 4) F11 57 1 43 33 F10 10A 20A 54 K1 34 13 23 X5 1 10A 0 F9 2 10A 170.0 66 MP1 0 2 16A 0 F2 4 4 1 0 5 0 2 1 0 2 0 2 1 0 2 l=130mm 535.0 470.0 …

2 Circuit Diagrams 59
00336812-020102LD3 Power supply circuit diagram (Sh. 2 of 2)
1.0mm²
1.0mm²
1.0mm²
1.0mm²
2
2
SMD-Placement System Siplace S23
Product status
Doc. status
Function status
=
Datum
Gepr.
Norm
Bearb.
Blatt
Urspr. Ers. f. Ers. d.NameDatumAenderungZustand
SIEMENS AG
Bl.
+
PL EA1 E
X3 X5X4 X6
12345678
12
F
E
D
C
B
A
GND
K1
5343
3323
X2
X6
X4 24
14 544434
66
3TK2805
24V AC
L2
3TK2804
A1
K2
L1 X1 X2
66
24V AC
K3
14
13
21
24V AC
+24V DC
00321113-xx
lefthand side
345678
A
B
C
D
E
F
6557433323
13
13
L1 X1 X3 X5
65
22
K3
K3
MP1
A2
L2
3414
24
44 58
24V AC
F10:2
54
44
K3
43
K1
53
+24V DC
To sheet 1
gr/bn
ye
terminal panel
To
From On push-button
wh/gr
rs
gr/pk
bk
vi
rd/bl
ye/bn
wh/ye
To S5 input X2kd:1
From On push-button
wh
gn
br
bl
wh/gn
bn/gn
Software release signal
Signaling circuit
Software release signal
gr
To S5 input X2kd:8
Control On
Signaling circuit
From EMERGENCY STOP circuit (to K1)
To On push-button
To ext. EMERGENCY STOP circuit (WPW)
To sheet 1 F7:2
24V AC switched
bk
To sheet 1 F10:2
bk
To sheet 1
Leh
Leh
Deu
02
01
02
02.09.98
23.01.98
04.12.98
04.12.98
Werner
#
Power supply circuit diagram
00336812-020102LD3
To On push-button
To key-operated switch
(to K2)
From EMERGENCY STOP circuit
To GND S5 Baugruppe X2kc:M
To S5 output X2kc:8
To S5 input X2kb:7
Software release signal

2 Circuit Diagrams 60
00336812-020102TD3 Power supply structure (Sh. 1 of 4)
F11
57
1
4333
F10
10A
20A
54
K1
34
13 23X5
1
10A
0
F9
2
10A
170.0
66
MP1
0
2
16A
0
F2
4
4
1
0
5
0
2
1
0
2
0
2
1
0
2
l=130mm
535.0
470.0
14 24X6
F4
PE
l=146mm
l=160mm
66
0
1
F1
24
85.0
NNN
5
N
Q1
31
X1 X3
1
L1
2
F8
l=146mm
l=164mm
0.0
167.0
73.0
10A 10A
1
5834 44
K2
F6
65
K3
0
3
10A
2
1
X200
2
6
0.0 21.2
6.0
Channel 1
PE PEPE
N
14X6X2 X4 X2 X4L244
4
2
65.0
0
F3
10A
2
1
0
0
5
6
6
X1 X3 X5
F7
0
2
1
53
F5
Channel 2
Power
L2
16A
3
0
On
Ready
L1
13 23 33 43
This lateral freedom of movement is needed to achieve optimum passage through the front panel.
It must be possible to move the main switch up to 2mm to the left/right on the top-hat rail.
The X200 terminals on the upper top-hat rail must be seated flush on the right, against the stop.
Note!
1234567
FF
E
C
B
A
TS35 - Top-hat rail
TS35 - Top-hat rail
TS35 - Top-hat rail
TS35 - Top-hat rail
TS35 - Top-hat rail
678
A
8
12345
B
C
D
E
Leh
Leh
Deu
02
01
02
02.09.98
23.01.98
04.12.98
04.12.98
Werner
#
Power supply structure
00336812-020102TD3
D
=
Datum
Gepr.
Norm
Bearb.
Blatt
Urspr. Ers. f. Ers. d.NameDatumAenderungZustand
SIEMENS AG
Bl.
+
PL EA1 E
270.0
370.0
65
6A
1
4
SMD-Placement System Siplace S23
Product status
Doc. status
Function status

2 Circuit Diagrams 61
00336812-020102TD3 Power supply structure (Sh. 2 of 4)
C
B
A
Attach end clamp
as as
V2
8
Connections must not protrude
123 678
12
7
V5
F
E
Single-phase
transformer
Fix both cable ducts
with additional rivets
the cable harness to the machine
31
12 22 32
14 24 34
2 T1
4 T2
01
13 23 33
11 21
Cables must not protrude over the top edge of the frame!
SIEMENS
Leh
Leh
Deu
02
01
02
03.09.98
23.01.98
04.12.98
04.12.98
Werner
#
Power supply structure
00336812-020102TD3
V1
8
A
F
Place K4 contactor flush on the right!
Join cables together with cable ties.
K4
N
-5% 120
PE
B
C
D
E
A1
21 NC
5 L3
Point for fixing
over the terminals!
6 T3
22 NC
1 L1
3 L2
0.0
Three-phase
=
Datum
Gepr.
Norm
Bearb.
Blatt
Urspr. Ers. f. Ers. d.NameDatumAenderungZustand
SIEMENS AG
Bl.
+
PL EA1 E
0.0
T2
- 535.0
T1
24
45
170.0
+5%
5
150 0
8
V4
V3
D
6
24
34
spacer
230 230
2
4
SMD-Placement System Siplace S23
Product status
Doc. status
Function status
transformer