89www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Operation
After the system is installed and programmed, the only actions required
from the operator are to switch on the system, run the program for the
workpiece, and shut down the system at the end of the work period.
Starting the System and Running a
Program
1. Switch on the DispenseMotion controller, monitor, and
robot.
2. Double-click the DispenseMotion icon to open the
dispensing software.
3. Click HOME.
The robot moves the camera to the home position (0, 0, 0)
and the system is ready.
4. Enable the dispensing system, including the valve controller. Refer to
the dispensing equipment manuals as needed.
5. Open the program file for your application.
6. Place the workpiece in the correct location on the fixture
plate.
7. Press the START button on the front of the robot, or click
RUN on the monitor.
8. When necessary, refer to the dispensing system manuals
to refill the dispenser.
9. If an emergency occurs, press the EMERGENCY STOP
button.
EMERGENCY
STOP button
START button
DISPENSER
PURGE button
Running a Program by Scanning a QR Code
PREREQUISITES
QR code scanning is enabled. Refer to “AppendixD, QR Code Scanning Setup” on page134 to enable QR
code scanning.
A QR code is present on the robot work surface and is associated with a program. Refer to “AppendixD, QR
Code Scanning Setup” on page134 to associate a QR code with a program.
1. Position the workpiece on the fixture plate.
2. Press the START button on the front of the robot, or click RUN on the monitor.
The system jogs to the predefined location where a QR code is located, scans the QR code, opens the
associated program, and executes the program.

RV Series Automated Dispensing Systems
90 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Pausing During a Dispense Cycle
Press START at any time to pause the system during a dispense cycle; the system pauses at its current position.
NOTE: If the system is paused when the dispenser is open, pattern integrity will be compromised.
Purging the System
To purge the system, press the DISPENSER PURGE button.
NOTE: You can set up the system to purge automatically. Refer to “How to Set Up Auto Purge, Program Cycle
Limits, or Fluid Working Life Limits” on page84.
Updating Offsets
After running a program repeatedly for several hours, click NEEDLE Z DETECT (systems with tip detection)
or NEEDLE XY ADJUST (systems without a tip detection) to update the system to compensate for minute
changes that can occur after long periods of operation.
Refer to “How the System Responds to Needle Z Detect or Needle XY Adjust” on page57 for a detailed
description of the system response to a Needle XY Adjust selection.
Shutting Down the System
1. Click SYSTEM SETUP > EXIT to close the DispenseMotion
software. If prompted to save a file, select YES or NO.
2. Switch off the following components:
• DispenseMotion controller
• Monitor
• Robot
3. Refer to the dispensing system manuals for any special
shutdown instructions.
Part Numbers
Part # / Model R3V R4V R6V
Part #
(robot with fixed-
mount camera)
7363556 7363557 7363558
Part #
(robot with rotating-
mount camera*)
7363673 (base robot, no
vision)
7364066 (vision kit)
7363675 (base robot, no
vision)
7364066 (vision kit)
7363677 (base robot, no
vision)
7364066 (vision kit)
Part # Europe**
(robot with fixed-
mount camera)
7363572 7363573 7363574
Part # Europe**
(robot with rotating-
mount camera*)
7363674 (base robot, no
vision)
7364067 (vision kit)
7727235 (keyboard and
mouse)
7363676 (base robot, no
vision)
7364067 (vision kit)
7727235 (keyboard and
mouse)
7363678 (base robot, no
vision)
7364067 (vision kit)
7727235 (keyboard and
mouse)
*Order all part numbers listed. Vision kit includes camera, PC, and monitor.
**Complies with European safety regulations.

RV Series Automated Dispensing Systems
91www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Accessories
NOTE: For replacement parts, refer to the maintenance and parts guide, available at www.nordsonefd.com/
RobotMaintenanceGuide.
Safety Enclosures
Nordson EFD guarded safety enclosures integrate seamlessly with our complete line of
automated dispensing systems. Featuring external dispensing controls, a safety light curtain,
and an internal electrical control box and wireways for faster, safer setup, these CE-compliant
enclosures also fully comply with EU Machinery Directive 2006/42/EC.
Part # Description Compatible Robot Models
7362738 Small safety enclosure
R3V
7362766 Small safety enclosure, Europe
7362739 Large safety enclosure
R4V
7362767 Large safety enclosure, Europe
Pre-Configured Output Cables
Item Part # Description
7360551 Standard cable to connect the dispenser and the robot
7360761
Single voltage initiate cable to connect the dispenser and the robot
(provides different pigtails to connect to different dispensers /
controllers)
7360554
Dual voltage initiate cable to connect up to two dispensers / controllers
to the robot
:
7362573
I/O interface cable between the ValveMate
™
8000 and the robot when
the use of all four (4) ValveMate 8000 channels are required
7360558
Dual-connector cable to connect up to two PICO Toµch controllers to
the robot
7362356
Dual-connector cable to connect up to two Liquidyn
®
V10 controllers to
the robot
7362357
Dual-connector cable to connect up to two Liquidyn V200 controllers to
the robot
7362373
Single-connector cable to connect a Liquidyn V200 controller to the
robot