9 Station Software Overviews 9.7 Maintenance GUI 150 Technical Training FSE SIPLACE TX-Series 01/2018 Verification – Feeder Verification This function is to verify the feeder pick up posi- tion at the machine. The machin…

9 Station Software Overviews
9.7 Maintenance GUI
Technical Training FSE SIPLACE TX-Series 01/2018 149
Verification – Conveyor Rail Verification
This function check the parallelism of the con-
veyor rails with the PCB cameras and the outer
edge of each rail in the placement area.
Verification – Conveyor Motor Verification
This function to verify the transport motors de-
pending on the current and the defined limits.
Example/ Extract of the report.
Verification – Power Supply (SMPS)
This is the common function for the power sup-
ply (SMPS) and is available for X-Series S and
SX machine with X-module upgrade and all TX
machine.

9 Station Software Overviews
9.7 Maintenance GUI
150 Technical Training FSE SIPLACE TX-Series 01/2018
Verification – Feeder Verification
This function is to verify the feeder pick up posi-
tion at the machine.
The machine takes a picture of the real pickup
position without offsets, so that the user can see
if the drive system matches the pickup position.

9 Station Software Overviews
9.7 Maintenance GUI
Technical Training FSE SIPLACE TX-Series 01/2018 151
9.7.4.1 Power Supply Diagnostics GUI
The diagnostics function can be accessed as follows:
1. Click on to the maintenance GUI icon
2. Click on Verification icon
3. Click on the "Power supply" button and the
main menu opens
This window shows the diagnostics data main view:
1. Main view SMPS data from PS1 and CAP1
2. CSB shows the status of all safety signals
from the safety breaker
3. Data for the 160 VDC
4. Data for the 42 VDC
5. Data for the 28 VDC
6. Data for the 24 VDC
7. Data for PS1 and CAP1
If the start button has not yet been pressed, there is no switched voltage present here yet and the
switched voltages icons are highlighted red:
1. Overview voltages status
2. Number of voltage drops since last reset
3. Reset voltage drop counter
NOTICE
All signals or voltages which are interrupted when pressing the emergency stop button or
opening the machine covers will be counted by the voltage drop counter.