00198171-02_Technical_Training_FSE_TX-Series_EN.pdf - 第46页

4 Gantry System 4.9 Excercise: TX Gantry System 46 Technical Training FSE SIPLACE TX-Series 01/2018 Maintenance content Interval Equipment required Compressed air filter Workflow 3 Air gun Vacuum pump filter Workflow 3 A…

100%1 / 168
4 Gantry System
4.6 Analyze
Technical Training FSE SIPLACE TX-Series 01/2018 45
4.6 Analyze
Code Error description Possible cause Action
30362
30470
30471
X/Y Axis counting error
during reference run
Dirty scale
Dirty encoder
Wrong reader position
Defect reader/scale
Clean scale
Clean encode reader
Adjustment distance
between encode reader and
scale
Change encode reader and
adjustment
Check/change scale
Calibration of ZPC, travel
range after adjustment of
reader
30562
30468
33522
Gantries too close to
each other
Distance too close between
two gantries or two gantries
touched
Move one gantry away from the
other and conduct reference run
4.7 Main Parts Exchange / Setting / Calibration
Overview of the parts which require adjustment after exchange. For detailed information refer to the
service manual.
Gantry parts exchange Tools/ Setting Calibration
X Axis incremental encoder Distance from scale:
0.75 ± 0.2mm
Travel range and machine ZPC
Y Axis incremental encoder Distance from scale:
0.75 ± 0.2mm
Travel range and machine ZPC
Head plate temperature sensors Head and camera
The PCB camera
Machine ZPC
Board camera
Head and camera offset
Y Axis buffer Travel range
X scale Adjust encoder as above Travel range and machine ZPC
Y scale Adjust encoder as above Travel range and machine ZPC
Head adapter for the MHCU Switch adjustment Check/download eSW (firmware)
Head interface PCB Switch adjustment
To remove the air hoses an unlocking tool is required 03051853.
4.8 Gantry System and Base Machine - Overview
Maintenance
Maintenance item for base machine, for detail see maintenance job card.
Maintenance content Interval Equipment required
Magnetic surfaces of X/Y Axis All workflows Cleaning wipe
Clean gantry cables All workflows Cleaning wipe
X/Y Axis guidance rail All workflows SIPLACE tissue
X/Y Axis scale Workflow 2 Cleaning wipe, ethyl alcohol
IC camera for CPP/TH Workflow 2 Cleaning wipe
Head exhaust air filter Workflow 3 Air gun, Allen key
4 Gantry System
4.9 Excercise: TX Gantry System
46 Technical Training FSE SIPLACE TX-Series 01/2018
Maintenance content Interval Equipment required
Compressed air filter Workflow 3 Air gun
Vacuum pump filter Workflow 3 Air gun, Allen key
Gas pressure shock absorber Workflow 4 Cleaning wipe
Linear guide bearing of X/Y Axis Workflow 4 Kluber oil BEM 34-132 cartridge
Protection covers Workflow 4 Cleaning fluid for the covers
Magnetic surfaces of X/Y Axis All workflows Cleaning wipe
4.9 Excercise: TX Gantry System
1. Which of the following is false regarding the TX Gantry system?
A The head interface board for Gantry 1 and 2 can be exchanged (swapped over).
B Both X and Y Axes are driven by linear motors.
C The TX gantry reference run is the same with X-Series S machine.
D MGCU is used for X and Y motor control.
2. Which action should be performed after exchange of the Y Axis encoder reader?
A Adjust the distance (0.75mm) between encode reader and scale.
B Calibrate travel range for both gantries.
C Calibrate machine zero point.
D All of the above.
3. Describe the machine reference run.
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
4 Gantry System
Room for Your Sketches and Notes
Technical Training FSE SIPLACE TX-Series 01/2018 47
Room for Your Sketches and Notes