3 Setting Up the Machine 3.2 Setting up the TX Machine - Calibrations Technical Training FSE SIPLACE TX-Series 01/2018 29 Base machine – Machine Setup/ Installation ● Machine transport height: 900mm to 950mm +- 15 (Only …

100%1 / 168
3 Setting Up the Machine
3.1 Setting up the TX Machine
28 Technical Training FSE SIPLACE TX-Series 01/2018
1. The balance point of the machine is not the center of the machine.
Attention: Don`t use the Input Side of the machine to lift up.
Please use the Output Side with a minimum fork of 617mm or with a distance between the
forks of 937mm.
Don`t move the machine outside of the center from the machine.
Move with fork next to the feet only; there is no other way to move the machine in line.
Leveling the machine
Please align the machine with 3 feet (1) and then fix the 4th foot (2) so that there is contact to the
ground.
It is easier to use the 2 feet at location 2 for leveling and fix last the 4th foot at location 1.
3 Setting Up the Machine
3.2 Setting up the TX Machine - Calibrations
Technical Training FSE SIPLACE TX-Series 01/2018 29
Base machine – Machine Setup/ Installation
Machine transport height: 900mm to 950mm +- 15 (Only 1 foot type required for all heights
with one adjustable screw).
Shaft spirit level should be put onto plate of lifting table.
Cover should be open in sector 1 and 2 to reach adjustable screw of feet.
3.2 Setting up the TX Machine - Calibrations
1. Log on as Machine service (1-3). 2. Select Automatic calibration.
3 Setting Up the Machine
3.2 Setting up the TX Machine - Calibrations
30 Technical Training FSE SIPLACE TX-Series 01/2018
3. Select calibration items 1-4(1).
For machines using the hardware option Va-
cuum tooling: Select also Vacuum tooling
(1a).
Click Next (2).
Note
Function Multistep calibration is only avail-
able for TX micron 15µm and 20/25 µm ma-
chines.
Multistep calibration replaces the previously
available board mapping and head mapping.
In this context Multistep calibration is not re-
quired for setting up the machine.
4. Select both Gantries (1).
Click Start (2).
5. Click Accept to save data.
NOTICE
Accuracy of TX micron machines have to be checked
After TX micron machines are setup and calibrated, the accuracy of the machines have to
be checked using the ACT tool. For detailed information refer to the ACT tool manual (order
number 00196351-xx).