Assembly Instructions, Converting the Powe r Supp ly 2 Safety check to DIN EN 60 204 12/2013 Edition 2.5 PE conductor test 151 2.5 PE conductor test 2.5.1 Permissible impedance values for the PE con ductors The PE test i…

2 Safety check to DIN EN 60 204 Assembly Instructions, Converting the Power Supply
2.4 High-voltage test 12/2013 Edition
150
WARNING 2
Parts of the system that are not rated for the test voltage must be disconnected. This particularly
applies to the monitor. 2
2.4.2 High-voltage testers
2
2.4.3 Performing the high-voltage test
– Disconnect the monitor.
– In the distributor box, connect the three-phase AC socket or socket with earthing contact to the
power cable for the machine, component table or MTC/MTC2. The test set-up is shown in fig-
ure 2 - 3
.
RISK OF DEATH 2
To protect the test set-up, you will need 2
a barrier chain
a red flashing light to signal the high-voltage tests and keep unauthorized personnel away from
the system.
Switch on the testing device and measure the equivalent leakage current with the following set-
tings:
- 1000 VAC (Canada 1500 VAC)
- Test duration 10 sec.
Measure the equivalent leakage current (active or apparent current).
Available testers
– GOSSEN-METRAWATT 204P
– METRAMACHINE 204/2,5 (complete system for tests to EN 60204-1
(VDE0113) consisting of Profitest 204, Profitest 204 HP, Signal 204,
Leadex 204, and Caddy 204
Power output 500 VA
Test duration 10 seconds
Tab. 2 - 2 High-voltage testers

Assembly Instructions, Converting the Power Supply 2 Safety check to DIN EN 60 204
12/2013 Edition 2.5 PE conductor test
151
2.5 PE conductor test
2.5.1 Permissible impedance values for the PE conductors
The PE test is used to test the continuity of the PE conductor system by means of a loop imped-
ance measurement to IEC 60364-6-61, 612.6.3. 2
PLEASE NOTE:
All the electrical connections must be fully installed on the machine, including those for the power
supply. 2
The impedances measured between the PE terminal and the test points must not exceed the val-
ues shown in the following table. 2
2.5.2 PE conductor testers
Smallest effective PE conductor cross-section in
branch to be tested
[mm²]
Maximum permissible impedance
[Ohm]
1.0 0.33
1.5 0.26
2.5 0.19
4.0 0.14
> 6.0 0.1
Tab. 2 - 3 Permissible impedance values for different PE conductor cross-sections
Available testers
– GOSSEN-METRAWATT 204P
– METRAMACHINE 204/2,5 (complete system for tests to EN 60204-1
(0113VDE 0113) consisting of Profitest 204, Profitest 204 HP, Signal 204,
Leadex 204, Caddy 204
Test duration 10 seconds
Tab. 2 - 4 PE conductor testers

2 Safety check to DIN EN 60 204 Assembly Instructions, Converting the Power Supply
2.5 PE conductor test 12/2013 Edition
152
2.5.3 Carrying out the PE conductor test
Measure the impedance of the PE conductor (yellow-green). Measure at the point furthest from
the PE conductor infeed point. The test duration should be at least 10 seconds.
Document the measured values in the test report.
Compare the measured values against those in table 2 - 3 on page 151.
Record whether the test was passed or not.
The machine may be released if the test is passed.
If the test is not passed, the error must be eliminated and the test repeated.