00193437-03_AI_PowerSupplyConversion_DE+EN.pdf - 第250页

7 Converting the power supply on the HS-60 / D4 / D1/D2 ma chine Assembly Instructions, Converting the Power Supply 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition 248 7.6.4 Replacing the …

100%1 / 282
Assembly Instructions, Converting the Power Supply 7 Converting the power supply on the HS-60 / D4 / D1/D2 machine
12/2013 Edition 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC
247
7.6.3 Removing the socket guard from the socket with earthing contact
Remove the Teddy socket guard, series 6310, from the socket with earthing contact using the
corresponding key.
7
7
Socket guard
with key
Socket
7 Converting the power supply on the HS-60 / D4 / D1/D2 machine Assembly Instructions, Converting the Power Supply
7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition
248
7.6.4 Replacing the main power cable
CAUTION
The electrical cables to each individual placement machine must be clearly identified and easy to
allocate without doubt. The regulations of the country in which the machine is operated apply.
The main power cable is connected to the U, V, W, N and PE terminals on terminal strip X1 (see
item X1 in Fig 7 - 12
, page 243).
Detach the wires of the main power cable from the U, V, W, N and PE terminals.
Detach the cable clamp from the cable holder.
Pull the cable out of the cable holder.
Push the main power cable (6 mm²) through the cable holder as far as the terminals on X1.
PLEASE NOTE: 7
Make sure that the cable bending radius is sufficient to prevent the wires being bent. 7
Connect the main power cable to the terminals on X1:
Wire 1 to U on X1,
Wire 2 to V on X1,
Wire 3 to W on X1,
Wire 4 to N on X1 and
Wire YEGN to PE on X1.
(See circuit diagram 00119185-050101LD4, sheet 1, page 254
)
Tighten the cable clamp.
Assembly Instructions, Converting the Power Supply 7 Converting the power supply on the HS-60 / D4 / D1/D2 machine
12/2013 Edition 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC
249
7.6.5 Overview of the parts - power supply unit - side view
Fig. 7 - 18 Overview of the parts - power supply unit - side view
EST Inrush current limiter board TG 31033-01
T1 Three-phase transformer
7.6.6 Converting the three-phase transformer T1 from 3 x 208 VAC to 3 x 400 VAC
Connect the cable from
terminal 1W6 to terminal 1W3
terminal 1V6 to terminal 1V3 and
terminal 1U6 to terminal 1U3.
Fig. 7 - 19 Primary terminals for transformer T1