7 Converting the power supply on the HS-60 / D4 / D1/D2 ma chine Assembly Instructions, Converting the Power Supply 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition 250 7.6.7 Reconnecting t…

Assembly Instructions, Converting the Power Supply 7 Converting the power supply on the HS-60 / D4 / D1/D2 machine
12/2013 Edition 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC
249
7.6.5 Overview of the parts - power supply unit - side view
Fig. 7 - 18 Overview of the parts - power supply unit - side view
EST Inrush current limiter board TG 31033-01
T1 Three-phase transformer
7.6.6 Converting the three-phase transformer T1 from 3 x 208 VAC to 3 x 400 VAC
Connect the cable from
terminal 1W6 to terminal 1W3
terminal 1V6 to terminal 1V3 and
terminal 1U6 to terminal 1U3.
Fig. 7 - 19 Primary terminals for transformer T1

7 Converting the power supply on the HS-60 / D4 / D1/D2 machine Assembly Instructions, Converting the Power Supply
7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition
250
7.6.7 Reconnecting the inrush current limiter board
The inrush current limiter board is located on the back of the front panel (see item EST in Fig. 7 -
18, page 249.
Move the following jumpers (see Fig. 7 - 20):
B3 from terminal X13 to terminal X12
B2 from terminal X23 to terminal X22 and
B1 from terminal X33 to terminal X32.
Reconnect the following wires:
(W) from terminal X14 to terminal X13,
(V) from terminal X24 to terminal X23 and
(U) from terminal X34 to terminal X33.
)
:
Fig. 7 - 20 Reconnecting the inrush current limiter board

Assembly Instructions, Converting the Power Supply 7 Converting the power supply on the HS-60 / D4 / D1/D2 machine
12/2013 Edition 7.7 HS-60 circuit diagrams
251
7.6.8 Installing the power supply unit
Carefully push the power supply unit into the housing until it reaches the stop.
Use the M8 hexagon socket-head screw to secure the unit at the bottom.
Check that the yellow-green PE wire is connected to the door.
Close the door.
PLEASE NOTE: 7
Make sure that the actuating shaft of the main switch slides easily into the opening in the ro-
tary button. 7
Use the machine key to lock the door.
7.6.9 Carry out the safety check to DIN EN 60 204
When the conversion is complete, carry out a safety check to DIN EN 60 204.
Follow the procedure described in section 2, page 146 onwards.
7.7 HS-60 circuit diagrams
3 x 208 VAC conversion kit for SIPLACE HS-60, for USA
00119085-050101LD4, 2 sheets, see page 252
and 253 7
SIPLACE HS-60 conversion kit, international
00119185-050101LD4, 2 sheets, see page 254
and 255 7