00193437-03_AI_PowerSupplyConversion_DE+EN.pdf - 第216页

6 Converting the power supply on the MTC Assemb ly Instructions, Converting the Power Supply 6.1 Tools and equipment 12/2013 Edition 214 6 Converting the power supply on the MTC This section describes how to convert the …

100%1 / 282
Assembly Instructions, Converting the Power Supply 5 Converting the power supply on S-27 HM machines/ and on component trolleys
12/2013 Edition 5.9 Converting the component trolley from 120 VAC to 230 VAC
213
5
Fig. 5 - 15 Component trolley power supply , new version
gnye
CO table
Ground
00301069-xx
Cable: Transformer - power supply
Sh.
Sh.
1.5mm²
04.
03.
01.
29.08.00
01.06.01
01.06.01 Tek
Tek
Wa. 11.07.1994
Eschenweck
Document status
Product status
Function status
X21ar
To
Control board
CO table
X36
DEMATICSIEMENS
00301239-0601011LD4
2
5
4
3
2
1
230V
115V
7V
0V
7V
New version
Interface
To
ModifiedStatus Date
PL EA 1 E2
Orig./Repl.f/Replaced byStand.Name
Check.
Stromlaufplan/Circuit diagram
Author
Date
Siplace SMD placement system
1
1
Transformer, CO trolley
PE
00300379-xx
Cable: CO table power supply
PE
Connection for
Grounding cable, CO trolley
Transformer cover
1
1
3
5
2
4
T2L
T5H
31
34
33
32
35
28V
8V
0V
28V
8V
0V
03009264-01
4AM4696-0BB40-0CA0
gnye
6 Converting the power supply on the MTC Assembly Instructions, Converting the Power Supply
6.1 Tools and equipment 12/2013 Edition
214
6 Converting the power supply on the MTC
This section describes how to convert the power supply unit for the matrix tray changer (MTC) on
the S-27 HM placement machine in order to adapt them to the supply networks in individual coun-
tries. 6
PLEASE NOTE: 6
The conversion can only be carried out if the MTC was supplied with the "USA conversion kit for
MTC" option (item no. 00116437-01). 6
6.1 Tools and equipment
Set of DIN 911 Allen keys
Set of slotted-head screwdrivers
Multimeter
6.2 Parts
The following parts are supplied with the accessory bag: 6
Jumper, gray, 3 x
item no. 00353338-01
5 x 20, T 6.3 A, micro-fuse, 10 x (for 120 VAC component table)
item no. 00806005-01
5 x 20, T 3.15 A, micro-fuse, 10 x (for 230 VAC component table)
item no. 00304938-01
Assembly Instructions, Converting the Power Supply 6 Converting the power supply on the MTC
12/2013 Edition 6.3 Modules to be converted
215
6.3 Modules to be converted
The following table lists those modules that have to be converted in order to adapt them to the
power supply network.
6.4 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC
Dock the MTC out of the placement machine.
RISK OF DEATH 6
Disconnect the MTC from the main power supply.
Remove the plug for the communication cable from the placement machine.
Take suitable action to ensure that the MTC cannot be connected to the power supply during
the conversion work.
Put up warning signs to indicate that work is being carried out on the electrical system.
Module Sub-module Ratings
Electronic panel Terminal panel X01
3 x 400 VAC ± 5%
3 x 208 VAC ± 5%
50 - 60 Hz
Power supply for
component feeder
table
Transformer T1
242 VAC / 50 Hz
230 VAC / 50 Hz
219 VAC / 50 Hz
126 VAC / 50 Hz
120 VAC / 50 Hz
114 VAC / 50 Hz
Fuse F1 3.15 AT at 242 VAC, 230 VAC, and 219 VAC
Adhesive label
3.15 AT at 242 VAC, 230 VAC, and 219 VAC
6.3 AT at 126 VAC, 120 VAC, and 114 VAC
Tab. 6 - 1 Modules to be converted