Assembly Instructions, Converting the Power Supply 6 Converting the power supply on the MTC
12/2013 Edition 6.5 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC
223
On terminal block X01, plug in three transverse jumpers between feed-through terminals 2-3,
6-7 and 10-11 (BR see Fig. 6 - 7
).
Leave the tripping current setting unchanged at 3.5 A on motor contactor Q01.
6
Fig. 6 - 7 MTC electronic panel - jumper set for 3 x 400 VAC
JMPJumper, 3 x 6
Q01 Motor contactor 6
X01 Terminal block 6
JMP (3 x 400 VAC) 6
6 Converting the power supply on the MTC Assembly Instructions, Converting the Power Supply
6.5 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition
224
6
Fig. 6 - 8 MTC - terminal panel X01, circuit diagram 3 x 400 VAC
1V1
1 2 3
2U1
2V1
2W1
4x2.5mm² CSA
1W1
1U1
3.7 kVA /50-60Hz
Oilflex 190
-W002
Transformer T01
3 x 208 VAC / 3 x 400 VAC
3 x 400 VAC / 230 VAC
L1
L2
50Hz / 60 Hz
L3
PE
Terminal panel X01
5x2.5mm² CSA
1 2 3 4
Oilflex 190
-W003
PE
L3.1
L1.1
L2.1
C
A A
JMP
JMP: 3 x 400 VAC
JMP JMP
N
Assembly Instructions, Converting the Power Supply 6 Converting the power supply on the MTC
12/2013 Edition 6.5 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC
225
6.5.2 Conversion work on the T1 transformer for the component table
6.5.2.1 Converting transformer T1 from 120 VAC to 230 VAC
Remove the tape roll container and the waste container.
Release the screws for the MTC cover on the component table side.
Lift off the cover.
6
Fig. 6 - 9 Position of transformer T1 for the component table
6