7 Converting the power supply on the HS-60 / D4 / D1/D2 ma chine Assembly Instructions, Converting the Power Supply 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition 244 7.6.2 Replacing the …

100%1 / 282
Assembly Instructions, Converting the Power Supply 7 Converting the power supply on the HS-60 / D4 / D1/D2 machine
12/2013 Edition 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC
243
Fig. 7 - 12 Power supply unit - front view
MS1 Motor circuit-breaker
MS1A Motor protection trip block
X1 Terminal strip for the main power cable
BU1 Service socket
M8 Locking screw for power supply unit
7 Converting the power supply on the HS-60 / D4 / D1/D2 machine Assembly Instructions, Converting the Power Supply
7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition
244
7.6.2 Replacing the motor protection trip block
The motor circuit-breakers only need to be retrofitted on the HS-60 and D4. On the D1/D2 they
only have to be readjusted.
The ZM-16-PKZ2 motor protection trip block, item number 00342495-01, must be used for 3x380
VAC, 3x400 VAC and 3x415 VAC supply voltages. The position of the motor protection trip block
is shown in Fig. 7 - 12
, item MS1A.
7.6.2.1 Removing the motor protection trip block
7
Fig. 7 - 13 Removing the motor protection trip block MS1A
7
Fig. 7 - 14 Lifting the protective flap
Turn the switch (1) counter-clockwise to the "0" position
Lift the
protective flap (2)
Assembly Instructions, Converting the Power Supply 7 Converting the power supply on the HS-60 / D4 / D1/D2 machine
12/2013 Edition 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC
245
7
Fig. 7 - 15 Releasing the yellow locking tab
7
Fig. 7 - 16 Removing the motor protection trip block MS1A
Use the screwdriver to push up the yellow locking tab (3)
Pull out the motor protection
trip block (4)