00193437-03_AI_PowerSupplyConversion_DE+EN.pdf - 第157页

Assembly Instructions, Converting the Power S upp ly 3 Converting the power supply on HF machines 12/2013 Edition 3.5 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC 155 3.5 Converting the power supply fr om …

100%1 / 282
3 Converting the power supply on HF machines Assembly Instructions, Converting the Power Supply
3.4 Modules to be converted 12/2013 Edition
154
3.3.2 Conversion kit for SIPLACE HF, international (3 x 400 VAC)
The conversion kit consists of the following parts:
ZM-16-PKZ2 motor protection trip block Item no. 00342495-01
Power supply conversion instructions
for SIPLACE HF/X/D/Di/MTC2/S-27HM/MTC/HS-60 Item no. 00193437-xx
12/2013 Edition, German and English
3.4 Modules to be converted
The following table lists those modules that have to be converted in order to adapt them to the
power supply network.
The connections for the station computer, LCD screens, uninterruptible power supply and compo-
nent tables need not be changed since they are connected to the placement machine's own 230
VAC system.
Module Sub-module Ratings
Power supply
00354626-xx
Transformer T1
00354630-xx
3 x 415 VAC ± 5%
3 x 400 VAC ± 5%
3 x 380 VAC ± 5%
3 x 230 VAC ± 5%
3 x 208 VAC ± 5%
Inrush current limiter
BRW3TT13084-01
03003056-xx
3 x 415 VAC ± 5%
3 x 400 VAC ± 5%
3 x 380 VAC ± 5%
3 x 230 VAC ± 5%
3 x 208 VAC ± 5%
Motor protection trip block
ZM-16-PKZ2
00342495-xx
3 x 415 VAC ± 5%
3 x 400 VAC ± 5%
3 x 380 VAC ± 5%
Motor protection trip block
ZM-32-PKZ2, USA option
00342496-xx
3 x 230 VAC ± 5%
3 x 208 VAC ± 5%
X102 service socket
Teddy socket guard, 6310 series,
white,
00357871-01
1 x 115 VAC (USA)
Main power cable, 4 mm²
3 x 415 VAC ± 5%
3 x 400 VAC ± 5%
3 x 380 VAC ± 5%
Main power cable (USA), 6 mm²
00345937-xx
3 x 230 VAC ± 5%
3 x 208 VAC ± 5%
Tab. 3 - 1 Modules to be converted
Assembly Instructions, Converting the Power Supply 3 Converting the power supply on HF machines
12/2013 Edition 3.5 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC
155
3.5 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC
RISK OF DEATH 3
Disconnect the machine correctly as described in section 1, page 145.
Disconnect the machine from the main power supply.
Take suitable action to ensure that the machine cannot be connected to the power supply dur-
ing the conversion work.
Put up warning signs to indicate that work is being carried out on the electrical system.
3
3
3
3 Converting the power supply on HF machines Assembly Instructions, Converting the Power Supply
3.5 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC 12/2013 Edition
156
3.5.1 Removing the power supply unit
Open the lock (item 3 in Fig. 3 - 1) on the cover (item 4 in Fig. 3 - 1 using the machine key.
Detach the holding cord from the cover.
Use the Allen key to loosen the M8 locking screw (item M8 in Fig. 3 - 2) on the lower front panel.
Pull the power supply unit out as far as the stop.
Fig. 3 - 1 Accessing the power supply unit
(1) Operator panel on the power supply side
(2) Main switch
(3) Door lock
(4) Cover
(5) Recess for power cable infeed