TT6094.ProductionHistory(YAMAHA_BRAND).pdf - 第15页
Y AMAHA Motor Co Ltd., IM Operation Mounter Soft Gr MDOC-SOFT5001 1 TT6094.Pr oductionHistory (Y AMAHA_BR AND).doc 15 / 53 releasing board fix ing and arriving Records a time from boar d fixing to finishing mounti…

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
14 / 53
stream.
Production Start Time is
recorded when a board starts
mounting before the previous
board arrives at the exit.
Time when the previous board
arrives at the exit of the lowest
stream.
Production Start Time is
recorded when a board starts
mounting before the previous
board arrives at the exit.
Finish Time 2001/06/08
11:50:47
Time when a board arrives at the
exit of the lowest stream.
Production started time or reset
time is recorded as Finish Time
when the next board starts
mounting before the previous
one arrives at the exit.
Time when the board arrives at
the exit of a mounting stage.
Production Start Time is
recorded as Finish Time when
the board starts mounting
before the previous board
arrives at the exit.
*1
Board
Count Max
10 The planned number of boards
mounted.
←
*1
Board Serial
No.
7 Serial Numbers of boards in
order of production in a program.
←
( Each stage gives serial
numbers to all boards mounted
on the stage)
*1
Finish Flag 0 0: Production finished
1: Uncompleted.
2: Restarted and completed
←
Production Finished Flag on a
mounting stage.
Sets the flag when it finishes
mounting.
Mount CT
(sec)
35.59 Time taken for mounting a
board.
Records a time between board
fixing and finishing mounting
except Mark Rec CT.
←
(YG300 starts recording from
when a board has been
transported on the mounting
point of U axis.)
Records about mounting tables
of a mounting stage.)
*1
Transfer CT
(sec)
4.76 Time spent on transferring a
board.
Time between board carrying
and fixing + Time between
←
*1

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
15 / 53
releasing board fixing and
arriving
Records a time from board fixing
to finishing mounting except a
Mark Rec CT.
However, Transfer CT is not
recorded when the machine is
-mounting
-recognizing Fiducial Mark
-recognizing Bad Mark
Standby CT
(sec)
1.24 Time when the board is waiting.
←
*1
Mark Rec
CT (sec)
2.41 Time spent on Fiducial Mark
Recognition of the board.
※Mark Rec CT is from starting
the head for Mark Recognition to
turning off after recognizing End
Mark.
←
(Records about mounting
tables of a mounting stage.)
*1
Pickup Error
3 The number of Pickup Errors
with the board. (Includes retries)
←
*1
Parts Vision
Error
2 The number of Parts Vision
Errors with the board. (Includes
retris)
←
*1
Co-planarity
Error
1 The number of Co-planarity
Errors occurring when the board
is under the operation.
(Includes retries)
This is displayed only in a
machine with a Co-planarity
Checker, or with Special
Function on.
←
V1.01
V2.01
V3.01
V3.11
only
Mark Vision
Error
1 The number of Mark Vision
Errors with the board.
(Includes retries)
←
*1
Transfer
Error
0 The number of Transfer Errors
with the board.
←
*1

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
16 / 53
Other Error 0 The number of other errors with
the board.
←
*1
Stop
Number
1 The number of times the
machine stops due to some
errors with the board.
←
*1
Operator
Call Time
(sec)
117 Time from when an error occurs
till when the error is cleared.
←
*1
Recovery
Time (sec)
246 Time from when the error is
cleared till when the machine
restarts.
←
*1
NG Blocks 0 The number of NG Blocks due to
Bad Mark Recognition.
←
*1
Mounted
Blocks
1 The number of Mounted Blocks.
←
*1
Upstream
Standby
Time (Sec)
1.20 None
Waiting time out of Standby CT
for a board from the upstream.
*2
Downstrea
m Standby
Time(Sec)
0.00 None
Waiting time out of Standby CT
for the down stream ready.
*2
Operation
Stop Time
*2
Board ID
(Edit:4)
123456789
0
Individual No. of each mounted
board. (Board ID)
←
*3
*1 Items outputted from the original versions(XG:V1.00, YG:V2.00, YS:V3.00)
*2 Items outputted from the original version of YS V3.00
*3 Board ID is outputted with data loaded by QR codes or barcodes when IT Option is available.
(Outputting Board ID of MIS is available with the following Versions)