TT6094.ProductionHistory(YAMAHA_BRAND).pdf - 第27页

Y AMAHA Motor Co Ltd., IM Operation Mounter Soft Gr MDOC-SOFT5001 1 TT6094.Pr oductionHistory (Y AMAHA_BR AND).doc    27 / 53 Continuous Production CT MAX A ~ D (Sec ) 1.23 None [Each S tage] Not output ted [ W CH] T…

100%1 / 53
YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
26 / 53
Upstream Standby
CT
MAX AD(Sec)
1.23
None
[Each Stage]
The longest time of being
standby on a stage for the
upper stream in a program.
[WCH]
Not outputted
*1
Upstream Standby
CT
MIN AD (Sec)
1.23
None
[Each Stage]
The shortest time of being
standby on a stage for the
upper stream in a program.
[WCH]
Not outputted
*1
Upstream Standby
CT
AVE AD (Sec)
1.23
None
[Each Stage]
The average time of being
standby on a stage for the
upper stream in a program.
[WCH]
Not outputted
*1
Downstream
Standby CT
MAX AD (Sec)
1.23
None
[Each Stage]
The longest time of being
standby on a stage for the
downstream in a program.
[WCH]
Not outputted
*1
Downstream
Standby CT
MIN AD (Sec)
1.23
None
[Each Stage]
The shortest time of being
standby on a stage for the
downstream in a program.
[WCH]
Not outputted
*1
Downstream
Standby CT
AVE AD(Sec)
1.23
None
[Each Stage]
The average time of being
standby on a stage for the
downstream in a program.
[WCH]
Not outputted
*1
YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
27 / 53
Continuous
Production CT
MAX AD (Sec)
1.23
None
[Each Stage]
Not outputted
[WCH]
The longest time of
Production CT in a
program.
Continuous Production CT
is a cycle time from when a
board arrives at the exit till
when the next one arrives
there.
By counting the CT except
the first board, it indicates
a cycle time with the
boards staying on each
stage of multi stage
machines.
*1
Continuous
Producton CT
MIN AD (Sec)
1.23
None
[Each Stage]
Not outputted
[MCH]
The shortest time of
Continuous Production CT
in the program.
*1
Continuous
Producton CT
AVE AD (Sec)
1.23
None
[Each Stage]
Not outputted
[MCH]
The average time of
Continuous Production CT
in the program.
*1
Production CT
MAX AD (Sec)
1.23
None
[Each Stage]
Not outputted
[MCH]
The longest time of
Production CT in the
program.
Production CT is a cycle
*1
YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
28 / 53
time from when it starts
producing till when it
arrives at the exit of the
last stage.
It indicates at how much
interval to produce boards.
The difference from
Continuous Production CT
is to count the first board,
which enables it to indicate
the average of the
program.
Production CT
MIN AD (Sec)
1.23
None
[Each Stage]
Not outputted
[MCH]
The shortest time of
Production CT.
*1
Production CT
AVE AD (Sec)
1.23
None
[Each Stage]
Not outputted
[MCH]
The average time of
Production CT.
*1
*1: Items outputted from the original versions (XG: V1.00, YG: V2.00, YS: V3.00)