TT6094.ProductionHistory(YAMAHA_BRAND).pdf - 第24页
Y AMAHA Motor Co Ltd., IM Operation Mounter Soft Gr MDOC-SOFT5001 1 TT6094.Pr oductionHistory (Y AMAHA_BR AND).doc 24 / 53 Not output ted NG Blocks 0 The number of NG Blocks due to Bad Mark in a program. [Each sta…

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
23 / 53
[WCH]
The number of Mark Vision
Errors on all stages in a
program.
(Includes retries)
Transfer Error 0 The number of Transfer
Error with the board
production on all stages in a
program.
(Includes retries)
[Each Stage]
The number of Transfer
Errors on a stage in a
program.
(Includes retries)
[WCH]
The number of Transfer
Errors on all stages in a
program.
(Includes retries)
*1
Other Error 0 The number of the other
errors with the board
production on all stages in a
program.
[Each Stage]
The number of the other
errors on a stage in a
program.
[WCH]
The number of the other
errors on all stages in a
program.
*1
Operator Call Time
(sec)
117 Total locked time in a
program from when an error
occurs till when it is cleared.
[Each Stage]
Total locked time on a
stage in a program from
when an error occurs till
when it’s cleared.
[WCH]
Not outputted
*1
Recovery Time 246 Total time in a program from
when an error is cleared till
when the machine restarts.
[each stage]
Total time on a stage in a
program from when an
error is cleared till when
the machine restarts.
[WCH]
*1

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
24 / 53
Not outputted
NG Blocks 0 The number of NG Blocks
due to Bad Mark in a
program.
[Each stage]
The number of NG Blocks
due to Bad Mark on each
stage in a program.
[MCH]
The number of NG Blocks
due to Bad Mark on the
last stage in a program.
*1
Mounted Blocks 1 The number of mounted
Blocks on all stages in a
program.
[Each stage]
The number of Mounted
Block on a stage in a
program.
[MCH]
Total number of Mounted
Blocks on the last stage in
a program.
*1
Upstream Standby
Time
1345 Total standby time for a
board coming from the
upstream machine.
When there is no board on
the mounting stage, it is
counted as Upstream
Standby time even if there is
a board on the exit position
waiting for the next machine
ready.
[Each Stage]
Total standby time for a
board coming from the
upstream.
[MCH]
Standby time of for a board
from the top stream of the
machine.
*1
Downstream
Standby Time
24 Total standby time for a
board coming to the
downstream machine.
When there are boards on
the mounting stage, and on
the exit stage waiting for the
next machine ready.
[Each Stage]
Total standby time on each
stage of the program due
to a matter of the
downstream.
[MCH]
Standby time of the lowest
stream of the machine.
*1
Working Ratio (%) 72.0 Ratio of an actual working [Each Stage] *1

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
25 / 53
time to an available time in a
program.
Refer to the following
explanation about for details.
Ratio of an actual working
time to an available time in
a program.
Refer to the following
explanation for details.
[MCH]
Ratio of an actual working
time to an available time in
all programs.
Refer to the following
explanation for the details.
Mount Points 55 Total mount points of one
board in the program.
It is totaled at the time of
board switching.
[Each Stage]
Total mount points of one
board on a stage in the
program.
It is totaled at the time of
board switching.
[WCH]
Total amount of parts
mounted on all mounting
stages in a program.
*1
Parts Consumption
445 Total amount of consumption
in a program.
It counts consumption spent
in Auto Running, not
includes parts consumption
such as picking up tests.
[Each Stage]
Total amount of
consumption on a stage in
a program. It counts
consumption spent in Auto
Running, not includes
parts consumption such as
picking up tests.
[MCH]
Total amount of
consumption on all stages.
It counts consumption
spent in Auto Running, not
includes parts components
such as picking up tests.
*1