TT6094.ProductionHistory(YAMAHA_BRAND).pdf - 第46页
Y AMAHA Motor Co Ltd., IM Operation Mounter Soft Gr MDOC-SOFT5001 1 TT6094.Pr oductionHistory (Y AMAHA_BR AND).doc 46 / 53 13. Feeder ID (Unit Log) In t he Feeder ID tab of History 2, coun ted informatio n is indi…

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
45 / 53
Pickup Timer 0.01 Pickup Timer of the parts. *1
Pickup Height 0.2 Pickup Height of the parts. *1
Mount Up Speed 20 Mount Speed of the parts. *1
Mount Up Timer 0.01 Mount Timer of the parts. *1
Mount Up Height 0.3 Mount Height of the parts. *1
Alignment Type None Alignment Type of the parts. *1
Threshold 55 Threshold Value of the parts. *1
*1 Items outputted from the original versions(XG:V1.00, YG:V2.00, YS:V3.00)
*2 Not counted when Retry Times is set as Immediate Stopping.
*3 V2.01 or later only
*4 YS Series V3.00 or later only
*5 YG/YS Series V2.01, V3.01, V3.11 only
*6 YS Series V3.27 or later only
<All Error Rate (%)>
The Total error rate which add up all parts data is indicated.
Pick Up Error Rate (%) : All parts total pick up error / All spent parts
Real Pick Up Error Rate (%) :(All parts total pick up error - All parts total no parts error) /
(All spent parts - All parts total no parts error)
Vision Error Rate (%) : All parts total vision error / All spent parts
No Parts Error Rate (%) : All parts total no parts error / All spent parts
Nozzle Error Rate (%) : All parts total nozzle error / All spent parts
( N/A : Not count “No Parts Error” with the parts – [Retry Times] is NORERY. )
12-2. File format
It indicates a version in the 1
st
row, “Grid with detail of each item” in the 2
nd
, and Error information in
order of occurrence below the 3
rd
row.
Fig. 12-2

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
46 / 53
13. Feeder ID (Unit Log)
In the Feeder ID tab of History 2, counted information is indicated for each Feeder ID. You can ensure
the status of usages and errors of each Feeder ID.
To use this function with YG300 or later, please select [Setup] – [Software Setting] - [History] -
[Unit Log] - [Log Setting] - [Management of ID Log] and check the box.
13-1. Grid with detail of each item
Chart. 13-1-1. Grid with detail of each item
<Item> <Example
>
<Contents> <Version>
Version V1.00 Version of the history recorded.
[User]: Set No is according to Feeder a set position.
[Soft]: Set No is according to internal values of the
application.
※1
Feeder Set No. 10 The numbers of the position on which a feeder is set.
※1
Feeder ID SSY-008-1
234567A
Feeder ID of a barcode on the feeder body.
※1
Feeder Type 8mm tape Records a feeder type.
※1

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
47 / 53
Parts Name C3216 Name of the parts whose feeder is set at the last.
※1
Feeder Counter 18 The number of the feeder driving (shooting).
※1
Pick Error
Counter
5 The number of Pick Errors with the feeder parts
※1
Pick Error % 0.000 Ratio of Pick Errors of the feeder parts to the number of
feeding times.
※1
Vision Error
Counter
5 The number of Vision Errors with the feeder parts.
※1
Vision Error % 0.000 Ratio of Vision Errors to the number of feeding times
※1
No Parts Error
Counter
5 Number of No Parts Errors with the feeder parts.
※1
※2
No Parts Error %
0.000 Ratio of No Parts Errors to the number of feeding times.
※1
Nozzle Error
Counter
2
The number of Nozzle Errors with the feeder parts.
※1
Nozzle Error % 0.000 Ratio of Nozzle Errors to the number of feeding times.
※1
Date 2009/01/1
4 12:34:00
Date it starts recording on the feeder.
※1
Last Update Date
2009/01/1
4 12:34:00
Date the latest feeder is used.
It is the day when it records [Feeding Times][Pickup
Error Times][No Parts Error Times][Nozzle Error Times].
It indicates the following information when the machine
turned on or when the feeder is set.
※1
Stroke Length/
Feed Time
168 Total length (mm) of a tape, which the feeder strikes.
※1
Smart Exit Count
15 The number of the feeder threaded.
※1
*1 Items outputted from the original version of YS:V3.00
*2 Not counted when Retry Times is set as Immediate Stopping.
13-2. File Format
It indicates a version in the 1
st
row, “Grid with detail of each item” in the 2
nd
, and Error information in
order of occurrence below the 3
rd
row.
Fig. 13-2