TT6094.ProductionHistory(YAMAHA_BRAND).pdf - 第19页
Y AMAHA Motor Co Ltd., IM Operation Mounter Soft Gr MDOC-SOFT5001 1 TT6094.Pr oductionHistory (Y AMAHA_BR AND).doc 19 / 53 S tage A(Each Mounting Log) Or MCH None Mounting stage which outputs the logs, or M C H *1…

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
18 / 53
7. Program Log (MIS)
In the Program Log screen, it indicates information about production of each program. One program
is regarded from when one of the board data is selected till when it is switched to the next board.
A drive inside the machine can save 1,000 results of programs produced.
Machine, which has Program Log of Each Stage, outputs a line of logs for each stage and a line of
Program Log of all programs.
Therefore, one board has two outputted lines of Program log of each stage and of all programs
together.
Explains comparing the old format of logs to the new format of each stage as follows.
Fig. 7-1
7-1. Grid with detail of each item
Chart 7-1-1 Grid with detail of each item
<Item> <Example>
<Contents>
(XG/YG Series)
<Contents>
(YS Series)
<Version>
Version V1.00 Version of the history
recorded.
←
*1
Program Name TOPAZ_TE
ST_1005
Name of a lot.
←
*1
Program Comment
For_CUK93
001
Comment of the lot
←
*1

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
19 / 53
Stage A(Each
Mounting
Log)
Or MCH
None
Mounting stage which
outputs the logs, or MCH
*1
Start Date 2001/06/08
11:50:04
Date the board data is
switched.
←
*1
Setup Date 2001/06/08
11:55:17
Time when the machine
starts auto-running after
setting up.
(Not recorded as Setup Date
with some errors like a data
error, even when the START
button is pushed)
←
*1
Finish Date 2001/06/08
15:43:25
Time when it switches to the
next board, or when the
power off.
[Each Stage]
Time when it finishes to
produce on the last
mounting stage.
[WCH]
Time when it switches to
the next board, or when
the power off.
*1
Board Count Max 10 Planned number of boards
mounted.
(Final counted value is
recorded if it is changed
during the production.)
←
*1
Produced Board 8 Actual number of board
mounted until finish.
(Uncompleted boards not
counted)
[Each Stage]
The number of boards
arriving at the exit of each
stage in a program.
[WCH]
The number of boards
arriving at the exit of the
last stage.
*1
Mount CT Max 35.59 The longest time taken for
mounting a board of all
[Each Stage]
The longest time taken
*1

YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
20 / 53
stages in a program. for mounting a board on a
stage in a program.
[WCH]
Not outputted
Mount CT Min 35.59 The shortest time taken for
mounting a board of all
stages in a program.
[Each Stage]
The shortest time taken for
mounting a board on a
stage in a program.
[WCH]
Not outputted
*1
Mount CT Ave 35.59 The average time taken for
mounting a board of all
stages in a program.
[Each Stage]
The average time taken for
mounting a board on a
stage in a program.
[WCH]
Not outputted
*1
Transfer CT Max 4.76 The longest time taken for
transferring a board of all
stages in a program.
[Each Stage]
The longest time taken for
transferring a board on a
stage in a program.
[WCH]
Not outputted
*1
Transfer CT Min 4.76 The shortest time taken for
transferring a board of all
stages in a program.
[Each Stage]
The shortest time taken for
transferring a board on a
stage in a program.
[WCH]
Not outputted
*1
Transfer CT Ave 4.76 The average time taken for
transferring a board of all
stages in a program.
[Each Stage]
The average time taken for
transferring a board on a
stage in a program.
[WCH]
Not outputted
*1
Standby CT Max 1.24 The longest time of all
stages for a board to
[Each Stage]
The longest time for a
*1