25 / 53
time to an available time in a
program.
Refer to the following
explanation about for details.
Ratio of an actual working
time to an available time in
a program.
Refer to the following
explanation for details.
[MCH]
Ratio of an actual working
time to an available time in
all programs.
Refer to the following
explanation for the details.
Mount Points 55 Total mount points of one
board in the program.
It is totaled at the time of
board switching.
[Each Stage]
Total mount points of one
board on a stage in the
program.
It is totaled at the time of
board switching.
[WCH]
Total amount of parts
mounted on all mounting
stages in a program.
*1
Parts Consumption
445 Total amount of consumption
in a program.
It counts consumption spent
in Auto Running, not
includes parts consumption
such as picking up tests.
[Each Stage]
Total amount of
consumption on a stage in
a program. It counts
consumption spent in Auto
Running, not includes
parts consumption such as
picking up tests.
[MCH]
Total amount of
consumption on all stages.
It counts consumption
spent in Auto Running, not
includes parts components
such as picking up tests.
*1
YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
26 / 53
Upstream Standby
CT
MAX AD(Sec)
1.23
None
[Each Stage]
The longest time of being
standby on a stage for the
upper stream in a program.
[WCH]
Not outputted
*1
Upstream Standby
CT
MIN AD (Sec)
1.23
None
[Each Stage]
The shortest time of being
standby on a stage for the
upper stream in a program.
[WCH]
Not outputted
*1
Upstream Standby
CT
AVE AD (Sec)
1.23
None
[Each Stage]
The average time of being
standby on a stage for the
upper stream in a program.
[WCH]
Not outputted
*1
Downstream
Standby CT
MAX AD (Sec)
1.23
None
[Each Stage]
The longest time of being
standby on a stage for the
downstream in a program.
[WCH]
Not outputted
*1
Downstream
Standby CT
MIN AD (Sec)
1.23
None
[Each Stage]
The shortest time of being
standby on a stage for the
downstream in a program.
[WCH]
Not outputted
*1
Downstream
Standby CT
AVE AD(Sec)
1.23
None
[Each Stage]
The average time of being
standby on a stage for the
downstream in a program.
[WCH]
Not outputted
*1
YAMAHA Motor Co Ltd.,
IM Operation
Mounter Soft Gr
MDOC-SOFT50011
TT6094.ProductionHistory(YAMAHA_BRAND).doc
27 / 53
Continuous
Production CT
MAX AD (Sec)
1.23
None
[Each Stage]
Not outputted
[WCH]
The longest time of
Production CT in a
program.
Continuous Production CT
is a cycle time from when a
board arrives at the exit till
when the next one arrives
there.
By counting the CT except
the first board, it indicates
a cycle time with the
boards staying on each
stage of multi stage
machines.
*1
Continuous
Producton CT
MIN AD (Sec)
1.23
None
[Each Stage]
Not outputted
[MCH]
The shortest time of
Continuous Production CT
in the program.
*1
Continuous
Producton CT
AVE AD (Sec)
1.23
None
[Each Stage]
Not outputted
[MCH]
The average time of
Continuous Production CT
in the program.
*1
Production CT
MAX AD (Sec)
1.23
None
[Each Stage]
Not outputted
[MCH]
The longest time of
Production CT in the
program.
Production CT is a cycle
*1