4 Operation
4.1 Settings in the Line Software
User Manual SIPLACE MeasuringFeeder X 03/2020 21
Polarized Capacitors
► Click on the tab(1) of the particular component.
► Click on the Electrical Characteristics tab(2) of the Object Properties view.
► In the Electrical Characteristics area, select Polarized Capacitor from the Component
type drop down menu(3).
► Adjust the electrical orientation of the component(4) if necessary.
► Enter the expected electrical values of the component(5).
Inductors
► Click on the tab(1) of the particular component.
► Click on the Electrical Characteristics tab(2) of the Object Properties view.
► In the Electrical Characteristics area, select Inductor from the Component type drop down
menu(3).
► Adjust the electrical orientation of the component(4) if necessary.
► Enter the expected electrical values of the component(5).

4 Operation
4.1 Settings in the Line Software
22 User Manual SIPLACE MeasuringFeeder X 03/2020
Diodes
► Click on the tab(1) of the particular component.
► Click on the Electrical Characteristics tab(2) of the Object Properties view.
► In the Electrical Characteristics area, select Diode from the Component type drop down
menu(3).
► Adjust the electrical orientation of the component(4) if necessary.
► Enter the expected electrical values of the component(5).
4.1.3 Marking a Component for Measuring
The procedure described here is explained using a resistor as an example.
► Click on the tab(1) of the particular component.
► Click on the Electrical Characteristics tab(2) of the Object Properties view.
► Mark the Electrical verification check box(3).

4 Operation
4.1 Settings in the Line Software
User Manual SIPLACE MeasuringFeeder X 03/2020 23
4.1.4 Defining Measurement Occurrence
If a component is selected for electrical verification, the first piece will be measured at each detec-
ted or potential package change, i.e. in case a new feeder is set up or after a foil torn error.
Optionally, an additional verification period can be defined if the component is to be measured
periodically. This value determines after how many pieces a component is measured again.
Optionally, an additional verification sequence can be defined: e.g. first check after 10, second
check after 100 and third check after 1000 components.
It also has to be specified how the individual components within the grey zone should be treated.
I.e., the components for which the system cannot determine to which packaging tape (old / new)
they belong to.
Defining a Verification Period
► Click on the tab(1) of the particular component.
► Click on the Electrical Characteristics tab(2) of the Object Properties view.
► Mark the Verification period check box(3).
► Enter the value in the entry field(3).