User Manual SIPLACE MeasuringFeeder X.pdf - 第4页
4 User Manual SIPLACE MeasuringFeeder X 03/2020 Table of Contents 4.1.5 Selecting the Nozzles for Measuring and Placement .. 25 4.1.6 Using Special Nozzles for Measuring Small Components .. 26 4.2 Handling the Measur…

3User Manual SIPLACE MeasuringFeeder X 03/2020
Table of Contents
Table of Contents
1 Introduction.. 5
1.1 Module Description.. 5
1.1.1 Typeplate and Serial Number.. 5
1.1.2 Technical Data.. 5
1.1.3 EU Declaration of Conformity.. 6
1.1.4 Correct Usage.. 6
1.1.5 Incorrect Usage.. 6
1.1.6 Environmentally-friendly disposal of materials and components.. 6
1.1.7 Electromagnetic compatibility (EMC).. 7
1.1.8 Use of original accessories and spare parts.. 7
1.2 Important Notes about this Manual.. 7
1.2.1 Contents and Filing of this Manual.. 7
1.2.2 Danger notes.. 7
1.2.3 Manufacturer's/supplier's liability.. 7
1.2.4 Release History.. 7
1.2.5 Further Information.. 8
1.2.5.1 How To Get Information.. 8
1.2.5.2 SIPLACE on the World Wide Web (WWW).. 8
2 Operational Safety.. 9
2.1 Safety Instructions.. 9
2.1.1 Conventions for the use of safety instructions and symbols.. 9
2.1.2 Staff Qualifications and Training.. 9
2.1.3 Important notes on operational safety.. 10
2.1.3.1 General.. 10
2.1.3.2 Safety of Operators and Other Persons.. 10
2.1.3.3 Safety of Plant and Equipment.. 10
2.2 ESD Guidelines.. 11
2.2.1 Definition of ESD.. 11
2.2.2 Important Measures to Protect Against Static Charging.. 11
2.2.3 Handling ESD Modules.. 11
2.2.4 Measurements and Modifications to ESD Modules.. 11
2.2.5 Dispatching ESD Modules.. 12
3 Function Description and Design.. 13
3.1 Function Description.. 13
3.2 Design.. 15
3.2.1 Overview.. 15
3.2.2 Contact Module.. 16
3.2.3 Electronic Components.. 16
3.2.4 Control Panel.. 17
4 Operation.. 19
4.1 Settings in the Line Software.. 19
4.1.1 Setting up the MeasuringFeeder X.. 19
4.1.2 Defining the Electrical Characteristics of a Component.. 20
4.1.3 Marking a Component for Measuring.. 22
4.1.4 Defining Measurement Occurrence.. 23

4 User Manual SIPLACE MeasuringFeeder X 03/2020
Table of Contents
4.1.5 Selecting the Nozzles for Measuring and Placement.. 25
4.1.6 Using Special Nozzles for Measuring Small Components.. 26
4.2 Handling the MeasuringFeeder X.. 27
4.3 Positioning and Docking the MeasuringFeeder X.. 27
4.4 Measuring Components.. 29
4.4.1 Measuring Components automatically.. 29
4.4.2 Measuring Components manually.. 31
4.4.3 Skipping the Measurement of Components.. 32
4.5 Handling Measurement Failures.. 33
4.5.1 Exchanging the faulty Component and Repeating the Measurement.. 34
4.5.2 Skipping the Measurement of a faulty Component.. 35
4.6 Removing the MeasuringFeeder X.. 36

1 Introduction
1.1 Module Description
User Manual SIPLACE MeasuringFeeder X 03/2020 5
1 Introduction
This manual provides technical information and describes how to operate the SIPLACE Measuring-
FeederX on SIPLACE placement machines.
1.1 Module Description
The SIPLACE MeasuringFeeder X is a special feeder module that provides the possibility to test
the electrical values of a component.
The SIPLACE MeasuringFeeder X is positioned on a changeover table like a standard 8mm X
feeder module.
1.1.1 Typeplate and Serial Number
The type plate with the serial number is positioned on the front of the right side panel of the
MeasuringFeederX.
1.1.2 Technical Data
SIPLACE MeasuringFeeder X
Length x Width x Height 581mm x 10.8mm x 200.5mm
Weight 1.5kg
Nominal Power 5W
Ambient Conditions for Packaging, Transportation and Storage
Temperature Range -25°C to 55°C
Atmospheric Humidity up to 95%
Ambient Pressure up to 1700m height without pressure equalization
Ambient Conditions for Module Operation
Temperature Range 15°C to 35°C
Atmospheric Humidity 30% to 75%
Ambient Pressure > 750mbar