JO-109-002_JG-0209.pdf - 第101页
4-13 JO-109 1 106-002 2. Feeder Measurement (5) Attach the master tapes to the tape feeder and set the feeder on the adjustment base of the jig. Master T apes Fig. D1 1 Master T ape Setting (For 8 mm T ape Feeder) Refere…

4-12
JO-109
1005-001
2. Feeder Measurement
(4) Press the [Meas] button. The "Measurement" window opens.
Fig. D10 "Measurement" Window
Note
(a) Use the following master tape respectively for each model.
(b) A master tape is required to be purchased for the
measurement.
Contact the marketing department or sales agency of
Hitachi High-Technologies for the details on the purchase
arrangements.
Reference
(a) Refer to "6. "Measurement" Window" in "Section 3" for
the details of the "Measurement" window.
(b) Refer to "2.4 Tape Guide and Support Suppressor" in the
instruction manual Tape Feeders for SIGMA-G4/G5 or
GXH Series for details.
Table D2
Models
Master
Tape JG Nos.
Part No.
Tape Width
Required
Q'ty
GT-*808*
GD-*808*
SL-4808*
JG-0009-12 KYH-M8601-00 8 mm
2 pcs.
GT-1216*
GD-1216*
JG-0009-16 KYH-M8603-00 16 mm
1 pcs.
GT-2432*
GD-2432*
JG-0009-17 KYH-M8604-00 32 mm
1 pcs.
GT-4456*
GD-4456*
JG-0009-18 KYH-M8605-00 56 mm
1 pcs.
GT-7200*
GD-7200*
JG-0009-20 KYH-M8610-00 72 mm
1 pcs.
GT-8800*
GD-8800*
JG-0009-21 KYH-M8611-00 88 mm
1 pcs.
GT-2404* JG-0009-22 KYH-M8612-00 4mm
2 pcs.

4-13
JO-109
1106-002
2. Feeder Measurement
(5) Attach the master tapes to the tape feeder and set the feeder on
the adjustment base of the jig.
Master Tapes
Fig. D11 Master Tape Setting (For 8 mm Tape Feeder)
Reference
Refer to "2.3 Attachment and Detachment of Master Tapes" in
"Section 4" for how to attach the master tapes.

4-14
JO-109
1005-001
2. Feeder Measurement
WARNING
If you wear a pacemaker, do not handle the tape
feeders.
The tape feeders use permanent magnets.
The pacemaker may be affected by the magnetism
and a serious accident will result.
CAUTION
•
Be sure not to drop any tape feeder. Otherwise,
your feet will get hurt or the feeder may be
damaged.
Carefully handle each tape feeder and never drop any.
•
When you install a tape feeder on the adjustment
base, avoid getting your ngers caught between
the end of the feeder and the adjustment base
and the connectors.
•
The master tapes are made of a thin metal.
Carefully handle the tapes to avoid cutting your
nger with the tape edges.
NOTICE
Conrm that the hook at the end of the tape feeder
is securely engaged and the suppressor is not set
aoat.
630 128 0127
00-0115-
Feeder Fixing Areas
Toggle Clamp Between End of Feeder and Adjustment Base
Fig. D12