JO-109-002_JG-0209.pdf - 第162页
4-74 JO-109 1005-001 4. Default Setting of Program for Feeder Measurement ¡ : Measurement Possible with Feeder Adjusting Jig r : The data measured by the height gauge can be transferred to the feeder adjusting jig. × :…

4-73
JO-109
1005-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D32
Feeder Models
GT28180 GT28183
Offset
Name
Lane #1 Origin Offset
○ × ○ ○
Lane #2 Origin Offset
○ × ○ ○
Lane #1 Offset X
○ ○ ○ ○
Lane #1 Offset Y
○ ○ ○ ○
Lane #1 Offset Z
△ △ △ △
Lane #2 Offset X
○ ○ ○ ○
Lane #2 Offset Y
○ ○ ○ ○
Lane #2 Offset Z
△ △ △ △
Sprocket Offset
× × × ○
Required Master Tape Models
JG-0009-12 JG-0009-12
Program Nos. (Initial Setting Mode)
100 101 102 103
Item
Type Name
GT28180
-8X2_ORG/XY
GT28180
-8X2_XY
GT28183
-8X2_ORG/XY
GT28183
-8X2_SPROCKET
Type Name Type ID Nos.
(1 to N)
1 1 1 1
Inspection Type Nos. (1 to 5)
3 2 5 4
# of Sprocket Feeding Times
(1 to 100)
90 90 90 90
Sprocket Feeding Interval
(1 to 100)
9 9 9 2
Sprocket Feeding Delay (ms)
0 0 0 0
# of Components per
Sprocket Circle
90 90 90 90
Component Pitch (mm)
2.000 2.000 2.000 2.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1 1
Fiducial Mark Position X
-3.650 -3.650 -3.650 -3.650
Fiducial Mark Position Y
-13.000 -13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256 256
# of Measured Pickup
Holes (1 or 2)
2 2 2 2
Measured Pickup Hole
Position #1 X
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #1 Y
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #2 X
9.500 9.500 9.500 9.500
Measured Pickup Hole
Position #2 Y
0.000 0.000 0.000 0.000
Feeder parameter le
(Before measurement)
GT28180-00000A.fdr GT28180-00000A.fdr GT28183-00005A.fdr GT28183-00004A.fdr
Feeder parameter le
(After measurement)
GT28180-00000B.fdr GT28180-00000B.fdr GT28183-00005B.fdr GT28183-00004B.fdr

4-74
JO-109
1005-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D33
Feeder Models
GD28180 GD28183
Offset
Name
Lane #1 Origin Offset
○ × ○ ○
Lane #2 Origin Offset
○ × ○ ○
Lane #1 Offset X
○ ○ ○ ○
Lane #1 Offset Y
○ ○ ○ ○
Lane #1 Offset Z
△ △ △ △
Lane #2 Offset X
○ ○ ○ ○
Lane #2 Offset Y
○ ○ ○ ○
Lane #2 Offset Z
△ △ △ △
Sprocket Offset
× × × ○
Required Master Tape Models
JG-0009-12 JG-0009-12
Program Nos. (Initial Setting Mode)
105 106 107 108
Item
Type Name
GD28180
-8X2_ORG/XY
GD28180
-8X2_XY
GD28183
-8X2_ORG/XY
GD28183
-8X2_SPROCKET
Type Name Type ID Nos.
(1 to N)
1 1 1 1
Inspection Type Nos. (1 to 5)
3 2 5 4
# of Sprocket Feeding Times
(1 to 100)
90 90 90 90
Sprocket Feeding Interval
(1 to 100)
9 9 9 2
Sprocket Feeding Delay (ms)
0 0 0 0
# of Components per
Sprocket Circle
90 90 90 90
Component Pitch (mm)
2.000 2.000 2.000 2.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1 1
Fiducial Mark Position X
-3.650 -3.650 -3.650 -3.650
Fiducial Mark Position Y
-13.000 -13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256 256
# of Measured Pickup
Holes (1 or 2)
2 2 2 2
Measured Pickup Hole
Position #1 X
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #1 Y
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #2 X
9.500 9.500 9.500 9.500
Measured Pickup Hole
Position #2 Y
0.000 0.000 0.000 0.000
Feeder parameter le
(Before measurement)
GD28180-00000A.fdr GD28180-00000A.fdr GD28183-00005A.fdr GD28183-00004A.fdr
Feeder parameter le
(After measurement)
GD28180-00000B.fdr GD28180-00000B.fdr GD28183-00005B.fdr GD28183-00004B.fdr

4-75
JO-109
1005-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D34
Feeder Models
GT38080 GT38083
Offset
Name
Lane #1 Origin Offset
○ × ○ ○
Lane #2 Origin Offset
○ × ○ ○
Lane #1 Offset X
○ ○ ○ ○
Lane #1 Offset Y
○ ○ ○ ○
Lane #1 Offset Z
△ △ △ △
Lane #2 Offset X
○ ○ ○ ○
Lane #2 Offset Y
○ ○ ○ ○
Lane #2 Offset Z
△ △ △ △
Sprocket Offset
× × × ○
Required Master Tape Models
JG-0009-12 JG-0009-12
Program Nos. (Initial Setting Mode)
110 111 112 113
Item
Type Name
GT38080
-8X2_ORG/XY
GT38080
-8X2_XY
GT38083
-8X2_ORG/XY
GT38083
-8X2_SPROCKET
Type Name Type ID Nos.
(1 to N)
1 1 1 1
Inspection Type Nos. (1 to 5)
3 2 5 4
# of Sprocket Feeding Times
(1 to 100)
90 90 90 90
Sprocket Feeding Interval
(1 to 100)
9 9 9 2
Sprocket Feeding Delay (ms)
0 0 0 0
# of Components per
Sprocket Circle
90 90 90 90
Component Pitch (mm)
2.000 2.000 2.000 2.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1 1
Fiducial Mark Position X
-3.650 -3.650 -3.650 -3.650
Fiducial Mark Position Y
-13.000 -13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256 256
# of Measured Pickup
Holes (1 or 2)
2 2 2 2
Measured Pickup Hole
Position #1 X
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #1 Y
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #2 X
9.500 9.500 9.500 9.500
Measured Pickup Hole
Position #2 Y
0.000 0.000 0.000 0.000
Feeder parameter le
(Before measurement)
GT38080-00000A.fdr GT38080-00000A.fdr GT38083-00005A.fdr GT38083-00004A.fdr
Feeder parameter le
(After measurement)
GT38080-00000B.fdr GT38080-00000B.fdr GT38083-00005B.fdr GT38083-00004B.fdr