3-20 JO-109 1005-001 6. "Measurement" Window 6. "Measurement" Window This window can be used to execute an accurate inspection of the feeder , view the results of the inspection, and create an accurac…

100%1 / 175
3-19
JO-109
1005-001
5. "System Setting" Window
(2) Outline of Each System Data
Control Mode
The set data is used to change the control mode.
"0" or "1" can be set.
0:
Through Mode
(Operator Conrmation Omitted at Accuracy Inspection)
1:
Step Mode
(Operator Conrmation Displayed)
Communication Timeout Value
Specify the time at which the "Communication Impossible" mode
should be detected in the RS232C serial communication.
Unit:
seconds
Alarm Buzzer Mode
Specify the period of time during which the buzzer should sound when
an error has occurred.
When "0" is set, the buzzer keeps on sounding until it is stopped with
the buzzer button.
"0" or "0.1 to 600.0 seconds (10 minutes)" can be set.
Log Data Folder
Specify the folder in which the inspection data log le should be saved.
Up to 62 characters can be used for the registration.
# of Feed Times from Sprocket
Specify the number of master tape idle feeding times required at the
start of the inspection.
A value "0 to 10" can be set.
Master Position #1 X and Y/Master Position #2 X and Y
The set parameters represent the inspection positions of the master
feeder.
3-20
JO-109
1005-001
6. "Measurement" Window
6. "Measurement" Window
This window can be used to execute an accurate inspection of the feeder,
view the results of the inspection, and create an accuracy table.
When you press the [Meas] button located at the bottom of each window, the
"Measurement" window opens.
Description of Each Button
[5]
[6]
[3]
[4][1]
[2]
Fig. C15 "Measurement" Window
[1] [START] button
When pressed, this button starts the measurement.
While the measurement is performed, the label on the button is changed
to "STOP". When the [STOP] button is pressed, the measurement is
interrupted temporarily.
[2] [RESET] button
This represents that the measurement is interrupted. This appears when
the measurement is interrupted temporarily with the [STOP] button in
[1].
[3] [Accur] button
When pressed, this button opens the "Accuracy Measurement Table"
window.
3-21
JO-109
1005-001
6. "Measurement" Window
[4] [Chart] button
When pressed, this button opens the "Chart" window.
[5] Display Control Button
When pressed, this button opens or closes the image window.
[6] [X/Y Measurement] button
The current X and Y positions are regarded as the results of each
measurement.
Description of Each Displayed Items
[7]
[6]
[3]
[5]
]2[ ]1[
[8][9]
[4]
Fig. C16
[1] Display Mark
The displayed mark will be spinning while this program is running.
[2] Sequence Speed
Displayed is the referential value of the sequence speed.
Ref.:
This value changes greatly according to the processed contents.
[3] Automatic Running Mode
Displayed is the automatic running mode. [RUN], [PAUSE], [STOP].
[4] Running Mode
Displayed are the current execution mode and a message.
[5] Feeder1, Feeder2, MS-ON
Displayed is the status of each signal that indicates whether or not
feeders are installed.
The box beside "Feeder 2" turns light blue (
) when the feeder is
installed.
The box beside "Feeder 1" turns light blue ( ) when the power is
turned "ON".
The box beside "MS-ON" turns light blue ( ) in the "Clamp" mode.