User manual SIPLACE X-series Setting up and commissioning From software version SR.70x.xx 01/2011 EN edition Adapting the used tape channel to the compone nt height 287 → Adjust the extension (item 2 in Fig. 4.5 - 1 , pa…

100%1 / 448
Setting up and commissioning User manual SIPLACE X-series
Adapting the used tape chute to the PCB conveyor height From software version SR.70x.xx 01/2011 EN edition
286
4.5 Adapting the used tape chute to the PCB conveyor
height
4.5.1 Adapting the used tape chute to the PCB -conveyor height
Depending on the PCB conveyor height, the length of the waste tape chute can be set so that the
pieces of tape are diverted directly into the waste tape container of the component trolley.
4
Fig. 4.5 - 1 Adapting the length of the used tape chute (X-series) - Dimensions in millimeters
(1) Used tape chute
(2) Extension
(3) Hexagonal nut M4, DIN 985, 2 x
4.5.1.1 Tools
Fork wrench, size 7
4.5.1.2 Setting the used tape chute to PCB conveyor height of 830 mm
Loosen the two M4 hexagonal nuts (item 3 in Fig. 4.5 - 1).
Remove the extension (item 2 in Fig. 4.5 - 1
).
4.5.1.3 Setting the used tape chute to PCB conveyor heights of 900 mm - 950 mm
Loosen the two M4 hexagonal nuts (item 3 in Fig. 4.5 - 1, page 286).
User manual SIPLACE X-series Setting up and commissioning
From software version SR.70x.xx 01/2011 EN edition Adapting the used tape channel to the component height
287
Adjust the extension (item 2 in Fig. 4.5 - 1, page 286) so that the distance between the bottom
edge and the floor does not exceed 320 mm + 20 mm (see Fig. 4.5 - 1
, page 286).
4.6 Adapting the used tape channel to the component
height
If X feeder modules are used, the component tapes work with a pocket height > 12 mm, so the
separating plate (item 1 in Fig. 4.6 - 1
) must be removed.
4
Fig. 4.6 - 1 Used tape channel, SIPLACE X-series
(1) Separating plate for tapes > 12 mm, removable
(2) DIN 93384 screw - M4x20, 2x
Setting up and commissioning User manual SIPLACE X-series
Adapting the used tape channel to the component height From software version SR.70x.xx 01/2011 EN edition
288
4.6.1 Safety instructions
WARNING 4
Switch the machine off at the main switch to remove the dividing plate.
Disconnect the machine from the power and compressed air supply.
Secure the machine to prevent it being switched on again, as described in Section 2.10
, page
94
.
Wait until the operating pressure for the tape cutter has dropped to 0 MPa.
Do not reach inside the used tape channel.
4.6.2 Removing the separating plate
Loosen the two hexagon head screws (item 2 in Fig. 4.6 - 1, page 287).
Pull out the separating plate (item 1 in Fig. 4.6 - 1
, page 287).