00196504-02_UM_X-Serie_SR70X_EN.pdf - 第316页
Tasks on the machine User manual SIPLACE X-series Indicator lamp status displays From so ftware version SR.70x.xx 01/2011 EN edition 316 5.7.3 Green indicator lamp s There is one green lamp on each side. They are connect…

User manual SIPLACE X-series Tasks on the machine
From software version SR.70x.xx 01/2011 EN edition Indicator lamp status displays
315
5.7 Indicator lamp status displays
The indicator lamps are used to signal operating statuses and malfunctions of the placement ma-
chine.
5.7.1 Description of the functions
Fig. 5.7 - 1 Operating status indicator lamps
L1 White indicator lamp, right
L2 Green indicator lamp, both lamps switched in parallel
L3 White indicator lamp, left
T Direction of PCB transport
5
5
5.7.2 Flashing frequencies
5
Normal flashing Green indicator lamp: 700 ms off, 700 ms on
White indicator lamp: 500 ms off, 500 ms on
Brief flashing 100 ms on, 1000 ms off
Rapid flashing 100 ms on, 200 ms off

Tasks on the machine User manual SIPLACE X-series
Indicator lamp status displays From software version SR.70x.xx 01/2011 EN edition
316
5.7.3 Green indicator lamps
There is one green lamp on each side. They are connected in parallel so that they are always syn-
chronized. The green lamp signals that the machine is in production mode or has been paused.
PLEASE NOTE 5
A combination of green and white lamps is used during a reference run, a manual function or a
calibration process - see section 5.7.5, page 320.
Status Meaning
Off The machine was paused (by the operator or by an alarm)
Normal flashing The machine is running in production mode, but is not currently
producing for one or both of the following reasons:
– Waiting for PCB in the input area.
– And/or waiting for the output area to become free
("conveyor jam" or waiting for a PCB to be removed)
Brief flashing The machine was paused
and
The machine is currently unable to produce: something still has to
be done, such as:
– Waiting for job and set-up data
– A reference run - a part of it (such as feeder module position
detection, or checking the nozzle configuration) is still pend-
ing.
– The axes must be moved before production starts.
On The machine is producing, even though a warning was output.

User manual SIPLACE X-series Tasks on the machine
From software version SR.70x.xx 01/2011 EN edition Indicator lamp status displays
317
5.7.4 White indicator lamps
There is one white lamp on each side. Each lamp is controlled separately.
The white lamps signal
– that a warning
a
or alarm
b
was output (as specified in the operator FRS (Feature Require-
ments Specification) for the machine software).
– The type of warning or alarm.
– The location on the machine concerned.
5.7.4.1 Locations
a) The warning is a message to inform the operator about an error that will soon require the operator's in-
tervention. The operator can ignore the message for a certain time. After this time, the message will be
output as an alarm.
b) An alarm is a message that indicates that the machine was paused / stopped. Operator intervention is required
immediately.
Associated lamp Associated location
Left-hand lamp A module on the left-hand side of the conveyor, such as:
–Table
–MTC
– Feeder module
– Waffle-pack tray carrier
– Nozzle changer
– Gantry, if there are two gantries per placement area
– A head or part of the head (segment, nozzle, etc) if there
are two gantries per placement area
– A conveyor track in a dual conveyor configuration
– A PCB in a dual conveyor configuration (exception: prob-
lems with fiducials)
– An electronics card that is accessible on this side of the
machine.
In this case, the other lamps remain unchanged.
On a four-gantry machine, these are the sides numbered 3 and 4.
Right-hand lamp A module on the right-hand side of the conveyor, as for the left-
hand lamp.
On a four-gantry machine, these are the sides numbered 1 and 2.