Station Software 705.04 SP2 / Installation Manual Ausgabe 06/2012 Edition
3.1 Upgrading from the 704.xx software version and higher
► Recalibrate the travelling ranges.
The travelling range measurement has been improved in 705.04 SP2. For this reason you are
advised to recalibrate the travelling ranges during installation of the 705.04 SP2 station
software.
► Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
► Save the calibration data for the placement heads (except Twin Head) in the EEPROM
(see section 7.9).
► Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
► Perform the closed vacuum calibration if Twin Heads are used.
3.2 Upgrading from the 703.02 or 703.02 SP1 software version
► Please pay attention to the Technical Information TI2010-10V02 and TI2010-10C02 when you
download the embedded software.
► Recalibrate the travelling ranges.
► Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
► SX-series placement machines in the field:
Due to the SW component counter, the HCU/GCU and the sensor modules have to be
programmed. For this, perform the work steps that are described in the Technical Information
TI2010-02V01 and TI2010-02C01 about programming HCU/GCU for the 704 upgrade. These
work steps can only be performed by the SIPLACE Service.
► SX 1/2 placement machine:
In order to use the "Long Board" option and the "Gantry Modularity" functionality, PCB mapping
and head mapping have to be performed.
► Placement machines with FC camera:
The entire placement head has to be calibrated.
► X4I placement machine:
The machine zero points, tables, nozzle changers, PCB reference corners and, if stationary
cameras are present the placement heads as well, have to be recalibrated (due to a changed
handling of double zero points on the X4I placement machine). No mapping is necessary.
► Save the calibration data for the placement heads (except Twin Head) in the EEPROM
(see section 7.9).
► Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
► Perform the closed vacuum calibration if Twin Heads are used.
9
Station Software 705.04 SP2 / Installation Manual Ausgabe 06/2012 Edition
3.3 Upgrading from the 703.01 software version
► Please pay attention to the Technical Information TI2010-10V02 and TI2010-10C02 when you
download the embedded software.
► Recalibrate the travelling ranges.
► Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
3.3.1 SX-series placement machines
► SX-series placement machines in the field:
Due to the SW component counter, the HCU/GCU and sensor modules have to be
programmed. For this, perform the work steps that are described in the Technical Information
TI2010-02V01 and TI2010-02C01 about programming HCU/GCU for the 704 upgrade. These
work steps can only be performed by the SIPLACE Service.
► Exchange the X/Y sensor modules to X-03068500-03 / Y-03064608-03.
► Install the 705.04 SP2 station software.
► Shut down the machine.
► Remove the tables.
► Switch on the machine again and wait until all error messages have been displayed and the
eSW download menu is enabled.
► Perform the eSW download for all subsystems.
► Reboot the machine.
► Place the tables.
The eSW download for the feeders starts automatically.
► Save the calibration data for the placement heads (except Twin Head) in the EEPROM
(see section 7.9).
► Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
► Perform the closed vacuum calibration if Twin Head are used.
► Calibrate the machine by performing the following steps:
► Calibrate the gantry axis (activate the options Y-axis: Encoder Alignment, Travel range,
X-axis: Parameterization, Y-axis: Mapping in the list).
► Perform PCB and head mapping.
► Start the production.
10
Station Software 705.04 SP2 / Installation Manual Ausgabe 06/2012 Edition
3.3.2 X-series placement machines
► Install the 705.04 SP2 machine computer software for two-computer operation, see chapter 5.
► Install the Vision computer software, see chapter 6.
► Shut down the machine.
► Remove the tables.
► Switch on the machine again and perform the eSW download.
► Reboot the machine.
► Place the tables. The eSW download for the feeders starts automatically.
► Save the calibration data for the placement heads in the EEPROM (see section 7.9).
► Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
► Perform the closed vacuum calibration if Twin Heads are used.
► Start the production.
3.4 Upgrading from 701.xx software versions (X4I placement
machine)
► Download the SIPLACE_UpgradePreparation.exe file (directory Upgrade_Preparation) from the
installation CD and execute the file.
► Reboot the machine and perform an eSW download for the placement heads.
► Install the 705.04 SP2 machine computer software for two-computer operation, see chapter 5.
► Install the Vision computer software, see chapter 6.
► Shut down the machine.
► Remove the tables.
► Switch on the machine again and perform the eSW download.
► Reboot the machine.
► Place the tables.
The eSW download for the feeders starts automatically.
► Save the calibration data for the placement heads in the EEPROM (see section 7.9).
► Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
► Perform the closed vacuum calibration if Twin Heads are used.
► Calibrate the nozzle changer.
► Calibrate the conveyor.
► Start the production.