00196771-04_IM_SSW_705_04_SP2_DE_EN.pdf - 第35页
Station Software 705.04 SP2 / Installation Manual Ausgabe 06/2012 Edition 5.4.7 Finalizing the installation NOTICE The status only lists the programs that ha ve just been installed. If, for instance, the current version …

Station Software 705.04 SP2 / Installation Manual Ausgabe 06/2012 Edition
NOTICE
The following screen only appears if applications are open which use files which must be
updated during installation of SIPLACE.
Figure 5-12: Open applications
► Close the applications or processes listed here by using Windows Task Manager and then click
the Retry button.
The installation program now installs additional programs on the machine computer.
34

Station Software 705.04 SP2 / Installation Manual Ausgabe 06/2012 Edition
5.4.7 Finalizing the installation
NOTICE
The status only lists the programs that have just been installed. If, for instance, the
current version of SIPLACE Vision was already installed, it is not listed here.
If errors occurred during installation, the status is indicated by the Error button being
displayed next to the program name instead of the Ok button.
► If you wish to read the log of the installation of any program, click the Ok (or Error) button next
to the name of the program. The Notepad is started and displays the appropriate file.
Figure 5-13: Finalizing the installation
► Click the Finish button.
CAUTION
► Wait a few seconds after you have clicked the Finish button, before you switch off
the computer / the machine!
As some installation steps are not performed until the end of the installation by the
InstallShield, the installation might otherwise be incomplete, what may cause
problems during further installations.
► Optionally, you can now install the SIPLACE Smart GUI.
CAUTION
In two-computer operation the Vision computer must also
be installed (see chapter 6)
before you shut down the machine computer, as the station will otherwise not boot
correctly due to version conflicts.
In one-computer operation the Vision computer software is automatically installed during
the station software installation.
35

Station Software 705.04 SP2 / Installation Manual Ausgabe 06/2012 Edition
5.5 Installing SIPLACE Smart GUI
The SIPLACE Smart GUI can optionally be installed after the station software has been installed. If
the station software has not been installed first, a corresponding error message is displayed.
► Insert the SIPLACE Smart GUI installation DVD in the drive.
It is read in automatically.
NOTICE
If auto start has been disabled for the drive, you must start the installation manually from
the Windows Explorer.
► Open the Explorer and start SmartGUI.exe under drive E by double clicking it.
The SIPLACE Choice Center dialog box is opened.
Figure 5-14: "SIPLACE Choice Center" dialog box
► Click the Smart GUI for station computer button.
Installation of the SIPLACE Smart GUI continues with the welcome screen.
36